40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Tue Sep 8 19:30:33 2009, rana, Update, PSL, c1psl rebooted for new RCPID database settings c1psl-term-dump.txt.gzC1PSL_FSS_RCPID.pngPicture_1.png
    Reply  Thu Sep 10 18:25:15 2009, rana, Update, PSL, c1psl rebooted for new RCPID database settings 
    Reply  Sat Sep 12 15:40:15 2009, rana, Update, PSL, RC response v. can temperature Picture_2.pngUntitled.pdf
Message ID: 1976     Entry time: Tue Sep 8 19:30:33 2009     Reply to this: 1983   1986
Author: rana 
Type: Update 
Category: PSL 
Subject: c1psl rebooted for new RCPID database settings 

The RC thermal PID is now controllable from its own MEDM screen which is reachable from the FSS screen. The slowpid.db and psl.db have been modified to add these records and all seems to be working fine.

Also, I've attached the c1psl startup output that we got on the terminal. This is just for posterity.

I'm also done tuning the PID for now. Using Kp = -1.0, Ki = -0.01, and Kd = 0, the can servo now has a time constant of ~10 minutes and good damping as can be seen in the StripTool snap below. These values are also now in the saverestore.req so hopefully its fully commissioned.

I bet that its much better now than the MINCO at holding against the 24 hour cycle and can nicely handle impulses (like when Steve scans the table). Lets revisit this in a week to see if it requires more tuning.

Attachment 1: c1psl-term-dump.txt.gz  2 kB  Uploaded Tue Sep 8 20:32:13 2009
Attachment 2: C1PSL_FSS_RCPID.png  8 kB  Uploaded Tue Sep 8 20:33:49 2009  | Hide | Hide all
C1PSL_FSS_RCPID.png
Attachment 3: Picture_1.png  65 kB  Uploaded Wed Sep 9 01:16:55 2009  | Hide | Hide all
Picture_1.png
ELOG V3.1.3-