Entry time: Mon Aug 17 04:16:13 2009
In reply to: 1915
|
Author: |
Yoichi |
Type: |
Update |
Category: |
PSL |
Subject: |
Reference cavity reflection looks bad |
|
|
Quote: | Rana, Yoichi
- We also moved the Refcav reflection camera to look at the leakage through a reflection steering mirror so that there's less chance of distortion. There was previously a W1 window in there as a pickofff. Also changed the camera to autogain so that we can see something.
- Re-aligned onto the refl pd.
- Tweaked alignment into RC. Mainly in yaw. Transmission went from 5V to 7V. In your face, Aso!
|
After our removal of the pick off window and Rana's re-alignment of the beam into the RC, the RC optical gain increased.
FSS was complaining about it by driving the PC feedback crazy.
I reduced the nominal common gain from 12.5dB to 11dB. |