40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Message ID: 16939     Entry time: Wed Jun 22 17:04:06 2022
Author: Deeksha 
Type: Summary 
Category: Electronics 
Subject: Characterising the AUX control loop 

[Cici, Deekha]

Setup loop to measure transfer function of control loop - the aim is to find the open loop gain of the system using the SR785 to inject noise (a swept sine) into the system and taking observations using the scope. We tried to calculate the gain algaebraically, in order to understand what our readings meant and what we can determine from them. Need to figure out how to run python script for the SR785, but took readings from cmd today.

Included - changes/additions made to circuit; frequency reponse obtained (need to check the frequency response as it does not look like the expected result, need to correct the loop itself, or increase the magnitude of the inserted noise as its possible that the noise is currently being suppressed by the system).

To do - circuit needs to be checked + laser lock improved - laser keeps leaving resonance while trying to take readings.

 

Attachment 1: after.jpeg  230 kB  Uploaded Wed Jun 22 18:09:37 2022  | Show | Hide all | Show all
Attachment 2: before.jpeg  256 kB  Uploaded Wed Jun 22 18:09:46 2022  | Hide | Hide all | Show all
before.jpeg
Attachment 3: freq_response.png  40 kB  Uploaded Thu Jun 23 11:50:38 2022  | Hide | Hide all | Show all
freq_response.png
ELOG V3.1.3-