Mon Feb 7 09:00:26 2022, Paco, Update, General, Scheduled power outage recovery
|
Mon Feb 7 15:32:48 2022, Yehonathan, Update, General, Y End laser controller
|
Mon Feb 7 16:53:02 2022, Koji, Update, General, Scheduled power outage recovery 
|
Wed Feb 9 11:56:24 2022, Anchal, Update, General, Bringing back CDS
|
Wed Feb 9 13:55:05 2022, Koji, Update, General, Bringing back CDS
|
Wed Feb 9 16:43:35 2022, Paco, Update, General, Scheduled power outage recovery - Locking mode cleaner(s)
|
Thu Feb 10 15:41:00 2022, Anchal, Update, General, Scheduled power outage recovery - Locking mode cleaner(s)
|
Thu Feb 10 17:57:48 2022, Anchal, Update, General, Scheduled power outage recovery - Locking mode cleaner(s)
|
Thu Feb 10 19:03:23 2022, Koji, Update, General, Scheduled power outage recovery - Locking mode cleaner(s)
|
Thu Feb 10 19:46:37 2022, Koji, Update, General, Scheduled power outage recovery - Locking mode cleaner(s)
|
Thu Feb 10 21:10:43 2022, Koji, Update, General, Video Mux setting reset 
|
Fri Feb 11 16:09:11 2022, Anchal, Update, General, Scheduled power outage recovery - Input power increased
|
Mon Feb 14 18:31:50 2022, Paco, Update, General, Scheduled power outage recovery - IMC recovery progress
|
Tue Feb 15 19:32:50 2022, Koji, Update, General, Scheduled power outage recovery - IMC recovery progress    
|
Tue Feb 15 19:40:02 2022, Koji, Update, General, IMC locking
|
Wed Feb 16 15:19:41 2022, Anchal, Update, General, Reconfigured MC reflection path for low power
|
Wed Feb 23 15:08:57 2022, Anchal, Update, General, Removed extra beamsplitter in MC WFS path
|
Thu Feb 24 14:32:57 2022, Anchal, Update, General, MC RFPD DCMON channel got stuck to 0
|
Thu Feb 24 19:26:32 2022, Anchal, Update, General, IMC Locking
|
Sun Feb 27 00:37:00 2022, Koji, Update, General, IMC Locking Recovery    
|
Sun Feb 27 01:12:46 2022, Koji, Update, General, IMC manual alignment procedure
|
Fri Feb 11 11:17:00 2022, Anchal, Update, General, Scheduled power outage recovery
|
Mon Feb 14 21:03:25 2022, Koji, Update, General, Scheduled power outage recovery
|
|
Message ID: 16676
Entry time: Wed Feb 23 15:08:57 2022
In reply to: 16674
Reply to this: 16677
|
Author: |
Anchal |
Type: |
Update |
Category: |
General |
Subject: |
Removed extra beamsplitter in MC WFS path |
|
|
As discussed in the meeting, I removed the extra beam splitter that dumps most of the beam going towards WFS photodiodes. This beam splitter needs to be placed back in position before increasing the input power to IMC at nominal level. This is to get sufficient light on the WFS photodiodes so that we can keep IMC locked for more than 3 days. Currently IMC is unlocked and misaligned. I have marked the position of this beam splitter on the table, so putting it back in should be easy. Right now, I'm trying to align the mode cleaner back and start the WFS loops once we get it locked. |