Message ID: 16512     Entry time: Thu Dec 16 12:21:16 2021     In reply to: 16499     Reply to this: 16516
Author: Anchal 
Type: Update 
Category: BHD 
Subject: Coil driver test failed for S2100619-v1 

Today I found one of the coil driver boards, S2100619 failed the test on CH2. There appears to be an extra phase lag after 10 kHz and some resonant-like feature at 7 kHz. This of course is very high-frequency stuff and maybe we don't care about these deviations. But it could mean something is off with the channel and could potentially lead to failure in the relevant frequency band in the future. I'll need help to debug this. Please see the attachment for details of test failure.

Attachment 1: D1100687_S2100619-v1_TF_CH2_Not_Matching.pdf  37 kB  Uploaded Thu Dec 16 13:50:54 2021  | Hide | Hide all
D1100687_S2100619-v1_TF_CH2_Not_Matching.pdf D1100687_S2100619-v1_TF_CH2_Not_Matching.pdf