40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Tue Feb 2 17:09:17 2021, yehonathan, Update, BHD, SOS assembly 
|
Tue Feb 2 18:24:54 2021, Koji, Update, BHD, SOS assembly
|
Thu Feb 4 15:14:55 2021, Yehonathan, Update, BHD, SOS assembly
|
Tue Feb 16 13:13:39 2021, Yehonathan, Update, BHD, SOS assembly
|
Tue Feb 16 15:29:01 2021, Koji, Update, BHD, SOS assembly
|
Tue Feb 16 22:59:36 2021, Yehonathan, Update, BHD, SOS assembly
|
Fri Feb 19 12:21:04 2021, Yehonathan, Update, BHD, SOS assembly
|
Fri Mar 26 10:25:37 2021, Yehonathan, Update, BHD, SOS assembly
|
Tue Apr 6 15:42:57 2021, Yehonathan, Update, BHD, SOS assembly
|
Fri Apr 9 20:54:54 2021, Yehonathan, Update, BHD, SOS assembly 
|
Mon Apr 12 17:30:11 2021, Yehonathan, Update, BHD, SOS assembly
|
Mon May 3 16:49:04 2021, Yehonathan, Update, BHD, SOS assembly 
|
Tue Jun 1 16:17:06 2021, Yehonathan, Update, BHD, SOS assembly
|
Wed Jun 2 01:03:19 2021, Koji, Update, BHD, SOS assembly
|
Fri Jun 18 19:02:00 2021, Yehonathan, Update, BHD, SOS assembly  
|
Fri Jun 18 23:53:08 2021, Koji, Update, BHD, SOS assembly
|
Tue Jun 22 17:05:26 2021, Yehonathan, Update, BHD, SOS assembly
|
Tue Jul 27 17:14:18 2021, Yehonathan, Update, BHD, SOS assembly
|
Tue Jul 27 20:12:53 2021, Koji, Update, BHD, SOS assembly
|
Mon Jun 28 12:35:19 2021, Yehonathan, Update, BHD, SOS assembly    
|
Tue Jun 29 20:45:52 2021, Yehonathan, Update, BHD, SOS assembly 
|
Thu Jul 1 16:45:25 2021, Yehonathan, Update, BHD, SOS assembly
|
Wed Jul 28 12:00:35 2021, Yehonathan, Update, BHD, SOS assembly
|
Thu Sep 23 18:18:07 2021, Yehonathan, Update, BHD, SOS assembly 
|
Tue Oct 26 10:17:14 2021, Yehonathan, Update, BHD, SOS assembly
|
Thu Oct 28 23:13:19 2021, Yehonathan, Update, BHD, SOS assembly   
|
Tue Nov 2 15:02:03 2021, Yehonathan, Update, BHD, SOS assembly
|
Tue Nov 2 22:50:30 2021, Koji, Update, BHD, SOS assembly
|
Mon Nov 8 17:22:27 2021, Yehonathan, Update, BHD, SOS assembly 
|
Tue Nov 9 11:11:37 2021, Yehonathan, Update, BHD, SOS assembly
|
Fri Nov 12 23:47:29 2021, Yehonathan, Update, BHD, SOS assembly
|
Tue Nov 16 17:42:46 2021, Yehonathan, Update, BHD, SOS assembly    
|
Tue Nov 16 18:28:53 2021, Koji, Update, BHD, SOS assembly 
|
Wed Nov 24 14:15:15 2021, Yehonathan, Update, BHD, SOS assembly
|
Wed Dec 1 12:57:08 2021, Yehonathan, Update, BHD, SOS assembly 7x
|
Mon Dec 6 18:23:04 2021, Yehonathan, Update, BHD, SOS assembly
|
Thu Dec 9 21:57:35 2021, Yehonathan, Update, BHD, SOS assembly 
|
Tue Dec 14 14:02:33 2021, Yehonathan, Update, BHD, SOS assembly 
|
Wed Dec 15 22:09:53 2021, Yehonathan, Update, BHD, SOS assembly
|
Thu Dec 16 18:16:36 2021, Yehonathan, Update, BHD, SOS assembly   
|
Fri Dec 17 17:50:17 2021, Yehonathan, Update, BHD, SOS assembly   
|
Fri Dec 17 19:16:45 2021, Koji, Update, BHD, SOS assembly
|
Fri Dec 17 22:16:07 2021, Yehonathan, Update, BHD, SOS assembly
|
Sat Dec 18 00:56:14 2021, Koji, Update, BHD, SOS assembly
|
Mon Dec 20 13:52:01 2021, Koji, Update, BHD, SOS assembly
|
Mon Dec 20 17:26:13 2021, Yehonathan, Update, BHD, SOS assembly 7x
|
Tue Dec 21 18:04:46 2021, Yehonathan, Update, BHD, SOS assembly
|
Tue Jan 4 18:27:23 2022, Paco, Update, BHD, SOS assembly -- PR3    
|
Wed Jan 5 19:18:06 2022, Yehonathan, Update, BHD, SOS assembly -- AS4  
|
Thu Jan 6 17:00:20 2022, Yehonathan, Update, BHD, SOS assembly -- LO2  
|
Thu Jan 6 17:16:51 2022, Yehonathan, Update, BHD, Using Peek screws/nuts
|
Fri Jan 7 17:59:45 2022, Yehonathan, Update, BHD, SOS assembly -- SR2  
|
Fri Jan 7 18:24:25 2022, Koji, Update, BHD, SOS assembly -- SR2
|
Mon Jan 10 14:00:44 2022, not Koji, Update, BHD, SOS assembly -- SR2
|
Tue Jan 11 09:53:14 2022, not Koji, Update, BHD, SOS assembly -- Peek screws and nuts
|
Thu Jan 13 16:08:00 2022, Yehonathan, Update, BHD, gluing magnets after AS1/4 misfortune
|
Fri Jan 14 17:33:10 2022, Yehonathan, Update, BHD, AS4 resurrection  
|
Wed Jan 19 18:15:34 2022, Yehonathan, Update, BHD, AS1 resurrection   
|
Thu Jan 20 12:10:51 2022, Yehonathan, Update, BHD, AS1 resurrection  
|
Mon Jan 24 17:58:21 2022, Yehonathan, Update, BHD, PR2 Suspension
|
Tue Jan 25 18:37:12 2022, TYehonathan, Update, BHD, PR2 Suspension  
|
Thu Feb 24 18:05:58 2022, Yehonathan, Update, BHD, Re-susspension of AS1 
|
Wed Mar 2 14:02:43 2022, Yehonathan, Update, BHD, Re-susspension of AS1
|
Thu Mar 3 17:09:46 2022, Paco, Update, BHD, Re-susspension of AS1
|
Mon Mar 7 16:56:08 2022, Yehonathan, Update, BHD, Re-susspension of AS1  
|
Mon Mar 7 18:53:16 2022, Koji, Update, BHD, Re-susspension of AS1
|
Tue Mar 8 12:24:13 2022, Yehonathan, Update, BHD, Re-susspension of AS1  
|
Tue Mar 8 19:29:36 2022, Paco, Update, BHD, Re-balance of AS1
|
Wed Mar 9 09:35:26 2022, Paco, Update, BHD, Re-balance of AS1
|
|
Message ID: 16491
Entry time: Mon Dec 6 18:23:04 2021
In reply to: 16489
Reply to this: 16497
|
Author: |
Yehonathan |
Type: |
Update |
Category: |
BHD |
Subject: |
SOS assembly |
|
|
I installed OSEMs on the LO1 SOS. To my surprise, the side magnet is not in the center of the side OSEM. It completely misses the LED as can be seen in the attachment.
Looking at the CAD model, it turns out the position of the OSEM on the left side plate is different from the position of the OSEM on the right side plate in the SOS tower.
We need to take the optic down, swap the right and left side blocks, and resuspend it.
There is not enough 🤦🏻♂️in the world |
|
|