Mon Sep 20 20:43:38 2021, Tega, Update, Electronics, Sat Amp modifications
|
Wed Sep 22 17:22:59 2021, Tega, Update, Electronics, Sat Amp modifications
|
Mon Oct 4 18:35:12 2021, Paco, Update, Electronics, Satellite amp box adapters  
|
Mon Oct 4 20:46:08 2021, Koji, Update, Electronics, Satellite amp box adapters
|
Thu Oct 7 02:04:19 2021, Koji, Update, Electronics, Satellite amp adapter chassis
|
|
Message ID: 16377
Entry time: Mon Oct 4 18:35:12 2021
In reply to: 16356
Reply to this: 16378
|
Author: |
Paco |
Type: |
Update |
Category: |
Electronics |
Subject: |
Satellite amp box adapters |
|
|
[Paco]
I have finished assembling the 1U adapters from 8 to 5 DB9 conn. for the satellite amp boxes. One thing I had to "hack" was the corners of the front panel end of the PCB. Because the PCB was a bit too wide, it wasn't really flush against the front panel (see Attachment #1), so I just filed the corners by ~ 3 mm and covered with kapton tape to prevent contact between ground planes and the chassis. After this, I made DB9 cables, connected everything in place and attached to the rear panel (Attachment #2). Four units are resting near the CAD machine (next to the bench area), see Attachment #3. |
|
|
|
|
|