Mon Sep 20 15:42:44 2021, Ian MacMillan, Summary, Computers, Quantization Code Summary  
|
Wed Sep 22 14:22:35 2021, Ian MacMillan, Summary, Computers, Quantization Noise Calculation Summary
|
Mon Sep 27 12:12:15 2021, Ian MacMillan, Summary, Computers, Quantization Noise Calculation Summary
|
Mon Sep 27 16:03:15 2021, Ian MacMillan, Summary, Computers, Quantization Noise Calculation Summary
|
Mon Sep 27 17:04:43 2021, rana, Summary, Computers, Quantization Noise Calculation Summary
|
Thu Sep 30 11:46:33 2021, Ian MacMillan, Summary, Computers, Quantization Noise Calculation Summary  
|
Wed Nov 24 11:02:23 2021, Ian MacMillan, Summary, Computers, Quantization Noise Calculation Summary
|
Wed Nov 24 13:44:19 2021, rana, Summary, Computers, Quantization Noise Calculation Summary
|
Tue Dec 7 10:55:25 2021, Ian MacMillan, Summary, Computers, Quantization Noise Calculation Summary    
|
Fri Dec 10 13:02:47 2021, Ian MacMillan, Summary, Computers, Quantization Noise Calculation Summary    
|
Mon May 9 15:32:14 2022, Ian MacMillan, Summary, Computers, Quantization Noise Calculation Summary  
|
Fri Sep 2 13:30:25 2022, Ian MacMillan, Summary, Computers, Quantization Noise Calculation Summary 
|
|
Message ID: 16362
Entry time: Mon Sep 27 17:04:43 2021
In reply to: 16361
Reply to this: 16366
|
Author: |
rana |
Type: |
Summary |
Category: |
Computers |
Subject: |
Quantization Noise Calculation Summary |
|
|
I suggest that you
- change the corner frequency to 10 Hz as I suggested last week. This filter, as it is, is going to give you trouble.
- Put in a sine wave at 3.4283 Hz with an amplitude of 1, rather than white noise. In this way, its not necessary to do any subtraction. Just make PSD of the output of each filter.