Thu May 27 14:11:15 2021, Jordan, Update, SUS, CoM to Clamping Point Measurement for 3" Adapter Ring 
|
Tue Jun 1 14:26:23 2021, Jordan, Update, SUS, CoM to Clamping Point Measurement for 3" Adapter Ring
|
Wed Jun 2 01:08:57 2021, Koji, Update, SUS, CoM to Clamping Point Measurement for 3" Adapter Ring
|
|
Message ID: 16165
Entry time: Thu May 27 14:11:15 2021
Reply to this: 16169
|
Author: |
Jordan |
Type: |
Update |
Category: |
SUS |
Subject: |
CoM to Clamping Point Measurement for 3" Adapter Ring |
|
|
The current vertical distance between the CoM and the wire clamping point on the 3" Ring assembly is 0.33mm. That is the CoM is .33 mm below the clamping point of the wire. I took the clamping point to be the top edge of the wire clamp piece. see the below attachments.
I am now modifying the dumbell mechanism at the bottom of the ring to move the CoM to the target distance of 1.1mm. |
|
|
|
|