40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Wed Feb 24 22:13:47 2021, Jon, Update, CDS, Planning document for front-end testing
|
Fri Mar 5 17:48:25 2021, Jon, Update, CDS, Front-end testing  
|
Tue Mar 9 16:52:47 2021, Jon, Update, CDS, Front-end testing
|
Tue Mar 16 16:27:22 2021, Jon, Update, CDS, Front-end testing
|
Tue Mar 16 19:04:20 2021, gautam, Update, CDS, Front-end testing
|
Fri Mar 19 18:14:56 2021, Jon, Update, CDS, Front-end testing 
|
Wed Mar 24 19:02:21 2021, Jon, Update, CDS, Front-end testing
|
Mon Mar 29 17:55:50 2021, Jon, Update, CDS, Front-end testing
|
Tue Mar 30 18:21:34 2021, Jon, Update, CDS, Front-end testing
|
Tue Apr 6 07:19:11 2021, Jon, Update, CDS, New SimPlant cymac
|
Tue Apr 6 11:13:01 2021, Jon, Update, CDS, FE testing
|
Sat Apr 10 08:51:32 2021, Jon, Update, CDS, I/O Chassis Assembly
|
Thu Apr 29 10:51:35 2021, Jon, Update, CDS, I/O Chassis Assembly
|
Tue May 4 07:38:36 2021, Jon, Update, CDS, I/O Chassis Assembly
|
Tue May 11 16:29:55 2021, Jon, Update, CDS, I/O Chassis Assembly
|
Tue May 11 17:43:09 2021, Koji, Update, CDS, I/O Chassis Assembly
|
Fri May 28 11:16:21 2021, Jon, Update, CDS, Front-End Assembly and Testing   
|
Sun Jun 6 08:42:05 2021, Jon, Update, CDS, Front-End Assembly and Testing  
|
Tue Jun 22 16:53:01 2021, Ian MacMillan, Update, CDS, Front-End Assembly and Testing
|
Thu Jun 24 17:32:52 2021, Ian MacMillan, Update, CDS, Front-End Assembly and Testing  
|
Fri Jun 25 14:06:10 2021, Jon, Update, CDS, Front-End Assembly and Testing
|
Sat Apr 10 11:56:14 2021, Jon, Update, CDS, 40m LSC simPlant model
|
Tue Apr 13 16:24:38 2021, Ian MacMillan, Update, CDS, 40m LSC simPlant model
|
Mon Apr 19 13:15:20 2021, Ian MacMillan, Update, CDS, 40m LSC simPlant model
|
Wed Apr 21 10:03:01 2021, Ian MacMillan, Update, CDS, 40m LSC simPlant model
|
Wed Apr 21 11:01:37 2021, Rana, Update, CDS, 40m LSC simPlant model
|
Fri Apr 23 15:52:19 2021, Ian MacMillan, Update, CDS, 40m LSC simPlant model  
|
Sun Apr 25 21:21:02 2021, rana, Update, CDS, SUS simPlant model
|
Tue Apr 27 15:15:17 2021, Ian MacMillan, Update, CDS, SUS simPlant model 
|
Thu Apr 29 13:41:40 2021, Ian MacMillan, Update, CDS, SUS simPlant model
|
Fri Apr 30 12:52:14 2021, Ian MacMillan, Update, CDS, SUS simPlant model
|
Mon May 3 13:35:12 2021, Ian MacMillan, Update, CDS, SUS simPlant model
|
Tue May 4 14:55:38 2021, Ian MacMillan, Update, CDS, SUS simPlant model
|
Wed May 5 15:11:54 2021, Ian MacMillan, Update, CDS, SUS simPlant model
|
Thu May 6 16:13:24 2021, Ian MacMillan, Update, CDS, SUS simPlant model
|
Fri May 7 11:19:29 2021, Ian MacMillan, Update, CDS, SUS simPlant model
|
Wed May 12 13:06:15 2021, Ian MacMillan, Update, CDS, SUS simPlant model   
|
Fri May 21 09:44:52 2021, Ian MacMillan, Update, CDS, SUS simPlant model
|
Fri May 21 14:36:20 2021, Ian MacMillan, Update, CDS, SUS simPlant model
|
Thu Jun 3 13:06:47 2021, Ian MacMillan, Update, CDS, SUS simPlant model 
|
Mon Jun 7 17:49:19 2021, Ian MacMillan, Update, CDS, SUS simPlant model 
|
Wed Jun 9 13:50:48 2021, Ian MacMillan, Update, CDS, SUS simPlant model
|
Tue Jun 15 11:46:40 2021, Ian MacMillan, Update, CDS, SUS simPlant model 
|
Wed Jun 30 14:09:26 2021, Ian MacMillan, Update, CDS, SUS simPlant model 
|
Mon Aug 23 15:25:59 2021, Ian MacMillan, Update, CDS, SUS simPlant model
|
|
Message ID: 16130
Entry time: Tue May 11 16:29:55 2021
In reply to: 16116
Reply to this: 16131
|
Author: |
Jon |
Type: |
Update |
Category: |
CDS |
Subject: |
I/O Chassis Assembly |
|
|
Quote: |
Timing system set-up
The next step is to provide the 65 kHz clock signals from the timing fanout via LC optical fiber. I overlooked the fact that an SPX optical transceiver is required to interface the fiber to the timing slave board. These were not provided with the timing slaves we received. The timing slaves require a particular type of transceiver, 100base-FX/OC-3, which we did not have on hand. (For future reference, there is a handy list of compatible transceivers in E080541, p. 14.) I placed a Digikey order for two Finisar FTLF1217P2BTL, which should arrive within two days.
|
Today I brought and installed the new optical transceivers (Finisar FTLF1217P2BTL) for the two timing slaves. The timing slaves appear to phase-lock to the clocking signal from the master fanout. A few seconds after each timing slave is powered on, its status LED begins steadily blinking at 1 Hz, just as in the existing 40m systems.
However, some other timing issue remains unresolved. When the IOP model is started (on either FE), the DACKILL watchdog appears to start in a tripped state. Then after a few minutes of running, the TIM and ADC indicators go down as well. This makes me suspect the sample clocks are not really phase-locked. However, the models do start up with no error messages. Will continue to debug... |
|