40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Mon Mar 8 12:01:02 2021, Paco, Anchal, Summary, training, Investigate how-to XARM locking
|
Mon Mar 8 12:40:35 2021, gautam, Summary, training, Investigate how-to XARM locking
|
Mon Mar 8 19:22:56 2021, rana, Summary, SUS, IMC suspension characterization
|
Thu Mar 11 08:13:24 2021, Paco, Anchal, Update, SUS, IMC First Free Swing Test failed due to typo, restarting now
|
Tue Mar 16 19:13:09 2021, Paco, Anchal, Update, SUS, First success in Input Matric Diagonalization 
|
Wed Mar 17 11:57:54 2021, Paco, Anchal, Update, SUS, Tested New Input Matrix for MC1 
|
Wed Mar 17 16:30:46 2021, Anchal, Update, SUS, Normalized Input Matrices plotted better than SURF students 
|
Thu Mar 18 09:18:49 2021, Paco, Anchal, Update, SUS, Testing of new input matrices with new data 
|
Thu Mar 18 12:46:53 2021, rana, Update, SUS, Testing of new input matrices with new data
|
Fri Mar 19 10:49:44 2021, Paco, Anchal, Update, SUS, Trying coil actuation balance
|
Mon Mar 22 11:57:21 2021, Paco, Anchal, Update, SUS, Trying coil actuation balance 
|
Mon Mar 22 15:10:00 2021, rana, Update, SUS, Trying coil actuation balance
|
Mon Mar 22 19:07:50 2021, Paco, Anchal, Update, SUS, Trying coil actuation balance 8x
|
Tue Mar 23 09:16:42 2021, Paco, Anchal, Update, Computers, Power cycled C1PSL; restored C1PSL 
|
Wed Mar 24 09:23:49 2021, Paco, Update, SUS, MC3 new Input Matrix
|
Thu Mar 25 11:46:31 2021, Paco, Anchal, Update, SUS, MC2 Coil Balancing updates   
|
Thu Mar 25 15:31:24 2021, gautam, Update, IOO, WFS servos
|
Fri Mar 26 11:54:37 2021, Paco, Anchal, Update, SUS, MC2 Coil Balancing updates
|
Mon Mar 29 10:44:51 2021, Paco, Anchal, Update, SUS, MC2 Coil Balancing updates 
|
Mon Mar 29 17:11:54 2021, gautam, Update, SUS, MC2 Coil Balancing updates
|
Mon Mar 29 17:34:52 2021, rana, Update, SUS, MC2 Coil Balancing updates
|
Wed Mar 31 22:58:32 2021, Anchal, Paco, Update, SUS, MC2 Coil Balancing Test
|
Thu Apr 1 13:56:49 2021, Anchal, Paco, Update, SUS, MC2 Coil Balancing Test Results  
|
Thu Apr 1 18:01:06 2021, Anchal, Paco, Update, SUS, MC2 Coil Balancing Test Results Success??  
|
Thu Apr 1 18:48:45 2021, gautam, Update, SUS, MC2 Coil Balancing Test Results Success??
|
Thu Apr 1 21:13:54 2021, Anchal, Update, SUS, Matrix results, new measurement set to trigger
|
Fri Apr 2 14:51:20 2021, Anchal, Update, SUS, Bug found, need to redo the balancing
|
Tue Apr 6 18:46:36 2021, Anchal, Paco, Update, SUS, Updates on recent efforts
|
Wed Apr 7 17:38:51 2021, Anchal, Update, SUS, Trying to uncouple only PIT and YAW first    
|
Thu Apr 8 17:04:43 2021, Anchal, Paco, Update, SUS, First Successful Coil Balancing  
|
Fri Apr 9 13:13:00 2021, Anchal, Paco, Update, SUS, Faster coil balancing 
|
Fri Apr 9 17:41:12 2021, rana, Update, SUS, Faster coil balancing
|
Mon Apr 12 10:07:35 2021, Anchal, Update, SUS, What's F2A??
|
Tue Apr 13 09:51:22 2021, rana, Update, SUS, What's F2A??
|
Wed Apr 14 17:53:38 2021, Anchal, Update, SUS, Plan for calculating filter banks for output matrix aka F2A aka F2P
|
Thu Apr 15 11:41:43 2021, Anchal, Update, SUS, Proposed filters for output matrix aka F2A aka F2P
|
Fri Apr 16 11:36:36 2021, Anchal, Paco, Update, SUS, Tested proposed filters for POS colum in MC2 output matrix    
|
Fri Apr 16 15:47:58 2021, rana, Update, SUS, Tested proposed filters for POS colum in MC2 output matrix
|
Mon Apr 19 12:18:19 2021, Anchal, Paco, Update, SUS, Tested proposed filters for POS colum in MC2 output matrix  
|
Tue Apr 20 10:52:49 2021, Anchal, Paco, Update, SUS, AC gain coil output balancing for IMC   
|
Tue Apr 20 18:19:30 2021, Anchal, Update, SUS, MC2 coil balanced at DC  
|
Wed Apr 21 11:38:27 2021, Anchal, Paco, Update, SUS, MC2 Damping Gains Optimized 
|
Wed Apr 21 15:50:01 2021, Anchal, Paco, Update, SUS, MC2 Suspension Optimization summary
|
Wed Apr 21 18:49:29 2021, rana, Update, SUS, MC2 Suspension Optimization summary
|
Thu Apr 22 08:50:21 2021, Anchal, Update, SUS, MC2 Suspension Optimization summary
|
Mon Apr 26 18:55:39 2021, Anchal, Paco, Update, SUS, MC2 F2A Filters Tested  
|
Tue Apr 27 10:05:28 2021, Anchal, Paco, Update, SUS, MC1 and MC3 F2A Filters Tested   
|
Wed Apr 28 10:56:10 2021, Anchal, Paco, Update, SUS, IMC Filters diagnosed 7x
|
Wed Apr 28 17:09:11 2021, Anchal, Update, SUS, Tuned Suspension Parameters uploaded for long term behavior monitoring
|
Thu Apr 29 10:52:56 2021, Anchal, Update, SUS, IMC Trans QPD and WFS loops step response test 
|
Thu Apr 29 18:53:33 2021, Anchal, Update, SUS, IMC Suspension Damping Gains Test  
|
Mon May 3 16:24:14 2021, Anchal, Update, SUS, IMC Suspension Damping Gains Test Repeated with IMC unlocked  
|
Wed May 5 09:04:47 2021, Anchal, Update, SUS, New IMC Suspension Damping Gains uploaded for long term testing
|
Wed May 12 11:45:13 2021, Anchal, Paco, Summary, SUS, New IMC Settings are miserable  
|
Wed Jun 2 09:43:30 2021, Anchal, Paco, Summary, SUS, IMC Settings characterization   
|
Wed Jun 2 16:20:59 2021, Anchal, Paco, Summary, SUS, IMC Suspension gains reverted to old values
|
Sat May 15 14:54:24 2021, gautam, Update, SUS, IMC settings reverted
|
Thu May 20 10:35:57 2021, Anchal, Update, SUS, IMC settings reverted
|
Thu Apr 22 12:17:23 2021, Anchal, Paco, Update, SUS, MC1 and MC3 Suspension Optimization Summary
|
Thu Apr 22 14:22:39 2021, gautam, Update, SUS, Settings restored
|
Thu Apr 22 15:36:54 2021, Anchal, Update, SUS, Settings restored
|
Thu Apr 22 17:04:17 2021, gautam, Update, SUS, Settings restored
|
Sat Apr 10 10:07:47 2021, rana, Update, SUS, Faster coil balancing
|
Fri Apr 2 15:22:54 2021, gautam, Update, SUS, Matrix results, new measurement set to trigger
|
Sun Mar 28 14:16:25 2021, Anchal, Summary, SUS, MC3 new Input Matrix not providing stable loop
|
Mon Mar 29 17:07:17 2021, gautam, Summary, SUS, MC3 new Input Matrix not providing stable loop
|
Thu Mar 18 13:12:39 2021, gautam, Update, Computer Scripts / Programs, Omnigraffle vs draw.io
|
|
Message ID: 15939
Entry time: Thu Mar 18 12:46:53 2021
In reply to: 15937
Reply to this: 15943
|
Author: |
rana |
Type: |
Update |
Category: |
SUS |
Subject: |
Testing of new input matrices with new data |
|
|
Good Enough! Let's move on with output matrix tuning. I will talk to you guys about it privately so that the whole doesn't learn our secret, and highly sought after, actuation balancing.
I suspect that changing the DC alignment of the SUS changes the required input/output matrix (since changes in the magnet position w.r.t. the OSEM head change the sensing cross-coupling and the actuation gain), so we want to make sure wo do all this with the mirror at the correct alignment.
|