40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Mon Mar 8 12:01:02 2021, Paco, Anchal, Summary, training, Investigate how-to XARM locking
|
Mon Mar 8 12:40:35 2021, gautam, Summary, training, Investigate how-to XARM locking
|
Mon Mar 8 19:22:56 2021, rana, Summary, SUS, IMC suspension characterization
|
Thu Mar 11 08:13:24 2021, Paco, Anchal, Update, SUS, IMC First Free Swing Test failed due to typo, restarting now
|
Tue Mar 16 19:13:09 2021, Paco, Anchal, Update, SUS, First success in Input Matric Diagonalization 
|
Wed Mar 17 11:57:54 2021, Paco, Anchal, Update, SUS, Tested New Input Matrix for MC1 
|
Wed Mar 17 16:30:46 2021, Anchal, Update, SUS, Normalized Input Matrices plotted better than SURF students 
|
Thu Mar 18 09:18:49 2021, Paco, Anchal, Update, SUS, Testing of new input matrices with new data 
|
Thu Mar 18 12:46:53 2021, rana, Update, SUS, Testing of new input matrices with new data
|
Fri Mar 19 10:49:44 2021, Paco, Anchal, Update, SUS, Trying coil actuation balance
|
Mon Mar 22 11:57:21 2021, Paco, Anchal, Update, SUS, Trying coil actuation balance 
|
Mon Mar 22 15:10:00 2021, rana, Update, SUS, Trying coil actuation balance
|
Mon Mar 22 19:07:50 2021, Paco, Anchal, Update, SUS, Trying coil actuation balance 8x
|
Tue Mar 23 09:16:42 2021, Paco, Anchal, Update, Computers, Power cycled C1PSL; restored C1PSL 
|
Wed Mar 24 09:23:49 2021, Paco, Update, SUS, MC3 new Input Matrix
|
Thu Mar 25 11:46:31 2021, Paco, Anchal, Update, SUS, MC2 Coil Balancing updates   
|
Thu Mar 25 15:31:24 2021, gautam, Update, IOO, WFS servos
|
Fri Mar 26 11:54:37 2021, Paco, Anchal, Update, SUS, MC2 Coil Balancing updates
|
Mon Mar 29 10:44:51 2021, Paco, Anchal, Update, SUS, MC2 Coil Balancing updates 
|
Mon Mar 29 17:11:54 2021, gautam, Update, SUS, MC2 Coil Balancing updates
|
Mon Mar 29 17:34:52 2021, rana, Update, SUS, MC2 Coil Balancing updates
|
Wed Mar 31 22:58:32 2021, Anchal, Paco, Update, SUS, MC2 Coil Balancing Test
|
Thu Apr 1 13:56:49 2021, Anchal, Paco, Update, SUS, MC2 Coil Balancing Test Results  
|
Thu Apr 1 18:01:06 2021, Anchal, Paco, Update, SUS, MC2 Coil Balancing Test Results Success??  
|
Thu Apr 1 18:48:45 2021, gautam, Update, SUS, MC2 Coil Balancing Test Results Success??
|
Thu Apr 1 21:13:54 2021, Anchal, Update, SUS, Matrix results, new measurement set to trigger
|
Fri Apr 2 14:51:20 2021, Anchal, Update, SUS, Bug found, need to redo the balancing
|
Tue Apr 6 18:46:36 2021, Anchal, Paco, Update, SUS, Updates on recent efforts
|
Wed Apr 7 17:38:51 2021, Anchal, Update, SUS, Trying to uncouple only PIT and YAW first    
|
Thu Apr 8 17:04:43 2021, Anchal, Paco, Update, SUS, First Successful Coil Balancing  
|
Fri Apr 9 13:13:00 2021, Anchal, Paco, Update, SUS, Faster coil balancing 
|
Fri Apr 9 17:41:12 2021, rana, Update, SUS, Faster coil balancing
|
Mon Apr 12 10:07:35 2021, Anchal, Update, SUS, What's F2A??
|
Tue Apr 13 09:51:22 2021, rana, Update, SUS, What's F2A??
|
Wed Apr 14 17:53:38 2021, Anchal, Update, SUS, Plan for calculating filter banks for output matrix aka F2A aka F2P
|
Thu Apr 15 11:41:43 2021, Anchal, Update, SUS, Proposed filters for output matrix aka F2A aka F2P
|
Fri Apr 16 11:36:36 2021, Anchal, Paco, Update, SUS, Tested proposed filters for POS colum in MC2 output matrix    
|
Fri Apr 16 15:47:58 2021, rana, Update, SUS, Tested proposed filters for POS colum in MC2 output matrix
|
Mon Apr 19 12:18:19 2021, Anchal, Paco, Update, SUS, Tested proposed filters for POS colum in MC2 output matrix  
|
Tue Apr 20 10:52:49 2021, Anchal, Paco, Update, SUS, AC gain coil output balancing for IMC   
|
Tue Apr 20 18:19:30 2021, Anchal, Update, SUS, MC2 coil balanced at DC  
|
Wed Apr 21 11:38:27 2021, Anchal, Paco, Update, SUS, MC2 Damping Gains Optimized 
|
Wed Apr 21 15:50:01 2021, Anchal, Paco, Update, SUS, MC2 Suspension Optimization summary
|
Wed Apr 21 18:49:29 2021, rana, Update, SUS, MC2 Suspension Optimization summary
|
Thu Apr 22 08:50:21 2021, Anchal, Update, SUS, MC2 Suspension Optimization summary
|
Mon Apr 26 18:55:39 2021, Anchal, Paco, Update, SUS, MC2 F2A Filters Tested  
|
Tue Apr 27 10:05:28 2021, Anchal, Paco, Update, SUS, MC1 and MC3 F2A Filters Tested   
|
Wed Apr 28 10:56:10 2021, Anchal, Paco, Update, SUS, IMC Filters diagnosed 7x
|
Wed Apr 28 17:09:11 2021, Anchal, Update, SUS, Tuned Suspension Parameters uploaded for long term behavior monitoring
|
Thu Apr 29 10:52:56 2021, Anchal, Update, SUS, IMC Trans QPD and WFS loops step response test 
|
Thu Apr 29 18:53:33 2021, Anchal, Update, SUS, IMC Suspension Damping Gains Test  
|
Mon May 3 16:24:14 2021, Anchal, Update, SUS, IMC Suspension Damping Gains Test Repeated with IMC unlocked  
|
Wed May 5 09:04:47 2021, Anchal, Update, SUS, New IMC Suspension Damping Gains uploaded for long term testing
|
Wed May 12 11:45:13 2021, Anchal, Paco, Summary, SUS, New IMC Settings are miserable  
|
Wed Jun 2 09:43:30 2021, Anchal, Paco, Summary, SUS, IMC Settings characterization   
|
Wed Jun 2 16:20:59 2021, Anchal, Paco, Summary, SUS, IMC Suspension gains reverted to old values
|
Sat May 15 14:54:24 2021, gautam, Update, SUS, IMC settings reverted
|
Thu May 20 10:35:57 2021, Anchal, Update, SUS, IMC settings reverted
|
Thu Apr 22 12:17:23 2021, Anchal, Paco, Update, SUS, MC1 and MC3 Suspension Optimization Summary
|
Thu Apr 22 14:22:39 2021, gautam, Update, SUS, Settings restored
|
Thu Apr 22 15:36:54 2021, Anchal, Update, SUS, Settings restored
|
Thu Apr 22 17:04:17 2021, gautam, Update, SUS, Settings restored
|
Sat Apr 10 10:07:47 2021, rana, Update, SUS, Faster coil balancing
|
Fri Apr 2 15:22:54 2021, gautam, Update, SUS, Matrix results, new measurement set to trigger
|
Sun Mar 28 14:16:25 2021, Anchal, Summary, SUS, MC3 new Input Matrix not providing stable loop
|
Mon Mar 29 17:07:17 2021, gautam, Summary, SUS, MC3 new Input Matrix not providing stable loop
|
Thu Mar 18 13:12:39 2021, gautam, Update, Computer Scripts / Programs, Omnigraffle vs draw.io
|
|
Message ID: 15930
Entry time: Wed Mar 17 11:57:54 2021
In reply to: 15926
Reply to this: 15934
|
Author: |
Paco, Anchal |
Type: |
Update |
Category: |
SUS |
Subject: |
Tested New Input Matrix for MC1 |
|
|
[Paco, Anchal]
Paco accidentally clicked on C1:SUS-MC1_UL_TO_COIL_SW_1_1 (MC1 POS to UL Coil Switch) and clicked it back on. We didn't see any loss of lock or anything significant on the large monitor on left.
Testing the new calculated input matrix
- Switched off the PSL shutter (C1:PSL-PSL_ShutterRqst)
- Switched off IMC autolocker (C1:IOO-MC_LOCK_ENABLE)
- Uploaded the same input matrix as the current one to check writing function in scripts/SUS/InMatCalc/testingInMat.py . We have created backup text file for current settings in backupMC1InMat.txt .
- Uploaded the new input matrix in normalized form. To normalize, we first made each row vector unit vector and then multiplied by the norm of current input matrix's row vectors (see scripts/SUS/InMatCalc/normalizeNewInputMat.py)
- Switched ON the PSL shutter (C1:PSL-PSL_ShutterRqst)
- Switched ON IMC autolocker (C1:IOO-MC_LOCK_ENABLE)
- Locked was caught immediately. The wavefront sensor of MC1 shows usual movement, nothing crazy.
- So the new input matrix is digestable by the system, but what's the efficacy of it?
< Two inspection people taking pictures of ceiling and portable AC unit passed. They rang the doorbell but someone else let them in. They walked out the back door.>
Testing how good the input matrix for MC1 is:
- We loaded the input matrix butterfly row in C1:SUS-MC1_LOCKIN_INMATRX_1_4 to 8. This matrix is multiplied by C1:SUS-MC1_UL_SEN_IN and so on channels before the calibration to um and application of toher filters.
- We tried to look around on how to load the same filter banks on the signal chain of LOCKIN1 of MC1 but couldn't, so we just manually added gain value of 0.09 in this chain to simulate the calibration factor at the very least.
- We started the oscillator on LOCKIN 1 on MC1 with amplitude 1 and frequency 6 Hz.
- We added butterfly mode actuation output column (UL:1, UR:-1, LL:-1, LR:1), nothing happened to the lock of probably because of low amplitude we put in.
- Now, we plot the ASD of channels like C1:SUS-MC1_SUSPOS_IN1 (for POS, PIT, YAW, SIDE) to see if we see a corresponding peak there. No we don't. See attachment 1.
Restoring the system:
- Added 0 to the LOCKIN1 column in MC1 output matrix.
- Made LOCK1 oscillator 0 Amplitude, 0 Hz.
- Changed back gain on signal chain of LOCKIN1 on MC1.
- Added 0 to C1:SUS-MC1_LOCKIN_INMATRX_1_4 to 8.
- Switched off the PSL shutter (C1:PSL-PSL_ShutterRqst)
- Switched off IMC autolocker (C1:IOO-MC_LOCK_ENABLE)
- Wrote back the old matrix by scripts/SUS/InMatCalc/testingInMat3.py which used the backup we created.
- Switched ON the PSL shutter (C1:PSL-PSL_ShutterRqst)
- Switched ON IMC autolocker (C1:IOO-MC_LOCK_ENABLE)
|
|
|
|