40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Tue Mar 2 19:52:46 2021, gautam, Update, LSC, REFL55 demod board rework
|
Wed Mar 3 22:13:05 2021, gautam, Update, LSC, REFL55 demod board rework
|
Thu Mar 4 23:16:08 2021, Koji, Update, LSC, REFL55 demod board rework    
|
Fri Mar 5 13:53:57 2021, gautam, Update, LSC, REFL55 demod board rework
|
Fri Mar 5 15:31:23 2021, Koji, Update, LSC, REFL55 demod board rework
|
Fri Mar 5 16:24:24 2021, gautam, Update, LSC, REFL55 demod board re-installed in 1Y2 
|
Fri Mar 5 22:25:13 2021, gautam, Update, LSC, PRMI 1f SB locking recovered
|
|
Message ID: 15869
Entry time: Fri Mar 5 15:31:23 2021
In reply to: 15867
Reply to this: 15871
|
Author: |
Koji |
Type: |
Update |
Category: |
LSC |
Subject: |
REFL55 demod board rework |
|
|
Missed to note: The IF test was done at TP7 and TP6 using pomona clips i.e. brefore the preamp.
|