Wed Jan 20 18:07:09 2021, Anchal, Summary, BHD, HAM-A Coil Driver measurements before modifications 7x
|
Mon Jan 25 18:18:04 2021, Anchal, Summary, BHD, Satellite Amplifier Transfer Functions and noise 
|
Wed Feb 3 16:27:19 2021, Anchal, Summary, BHD, Satellite Amplifier Transfer Functions and noise After modifications    
|
Wed Feb 10 11:45:59 2021, Anchal, Summary, BHD, Satellite Amplifier Very Low frequency noise After modifications 6x
|
Wed Feb 10 15:07:50 2021, Anchal, Summary, BHD, Satellite Amplifier Output Offset measurements
|
Wed Feb 10 15:25:45 2021, gautam, Summary, BHD, Satellite Amplifier Output Offset measurements
|
Wed Feb 10 17:18:03 2021, Koji, Summary, BHD, Satellite Amplifier Output Offset measurements
|
Thu Feb 11 11:10:05 2021, Anchal, Summary, BHD, Satellite Amplifier Very Low frequency noise After modifications   
|
Thu Feb 11 16:58:52 2021, rana, Summary, BHD, Satellite Amplifier Very Low frequency noise After modifications
|
Thu Jan 28 12:53:14 2021, Anchal, Summary, BHD, HAM-A Coil Driver measurements before modifications    
|
Thu Jan 28 18:04:55 2021, Anchal, Summary, BHD, HAM-A Coil Driver measurements After modifications 
|
Thu Jan 28 21:44:45 2021, gautam, Summary, BHD, HAM-A Coil Driver measurements After modifications
|
Fri Jan 29 15:39:30 2021, Anchal, Summary, BHD, HAM-A Coil Driver measurements After modifications TF and Noise S2100027    
|
Tue Feb 2 11:57:46 2021, Anchal, Summary, BHD, HAM-A Coil Driver measurements After modifications TF and Noise S2100028    
|
|
Message ID: 15776
Entry time: Mon Jan 25 18:18:04 2021
In reply to: 15774
Reply to this: 15793
|
Author: |
Anchal |
Type: |
Summary |
Category: |
BHD |
Subject: |
Satellite Amplifier Transfer Functions and noise |
|
|
I took transfer function and noise measurement of satellite amplifier box's photodiode transimpedance circuit. For the measurement, I created a makeshift connector to convert backside DB25 into DB9 with the 4 channels for PDA input. The output was taken in differential form at the front PD Output port. To feed current to the circuit, I put in 12 kOhm resistors in series at the inputs, so the V/V transfer function measured was multiplied by 12 kOhm to get the transimpedance of the circuit.
Transfer Function Measurement details
- SR785 source out was fed into PDA input pins using a makeshift BNC-DB9-DB25 converter.
- The output from PDOut DB9 port was fed to test switch in D1900068 to separate differential signal.
- This differential signal was fed back to SR785 at input 2 in A-B configuration.
- Measurements are taken with file D1002818_TF.yml and D1002818_TF_LF.yml.
- A measurement of just cables without the DUT is taken as well.
- Commands.txt list all the commands used.
- All data is compiled and plotted in Plotting.ipynb
- D1100117_S2100029_TFandNoiseSpectrum.pdf shows all the transfer functions measured.
Spectrum Measurements
- Two pair of BNC cables were twisted together and clips were added at ends.
- One of the GND was connected to board GND. Rest were left unconnected to avoid ground loops.
- Each pair of signal was connected to PDOutP/N.
- The PDA inputs were shorted together to make zero input current to the board.
- Instrument noise with cables was measured by shorting the clips of the center cores and one of the shields of the two BNC cables together.
- Measurements were taken with file D1002818_SP.yml and D1002818_SP_LF.yml.
- Input referred current noise spectrum was calculated by dividing the output voltage noise spectrum by the measured transfer function.
- D1100117_S2100029_TFandNoiseSpectrum.pdf shows all the output votlage noise spectrum and input referred current noise spectrum measured.
Edit Wed Feb 10 15:14:13 2021 :
THE NOISE MEASUREMENT WAS WRONG HERE. SEE 40m/15799. |
|
|
|