40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Thu Aug 6 00:34:38 2020, Yehonathan, Update, BHD, Monte Carlo Simulations 8x
    Reply  Fri Aug 7 11:23:47 2020, rana, Update, BHD, Monte Carlo Simulations 
       Reply  Mon Aug 10 07:13:00 2020, Yehonathan, Update, BHD, Monte Carlo Simulations 8x
          Reply  Tue Aug 25 05:51:29 2020, Yehonathan, Update, BHD, Monte Carlo Simulations 8x
             Reply  Mon Sep 14 07:50:01 2020, Yehonathan, Update, BHD, Monte Carlo Simulations 10x
                Reply  Fri Oct 16 09:16:37 2020, Yehonathan, Update, BHD, Monte Carlo Simulations 8x
                   Reply  Thu Oct 22 11:48:08 2020, Yehonathan, Update, BHD, Monte Carlo Simulations 8x
                      Reply  Thu Dec 10 14:48:00 2020, Yehonathan, Update, BHD, Monte Carlo Simulations MCMCLance_NoiseBudget_Example.pdfIFO_Check.pdf
                         Reply  Fri Dec 11 09:28:52 2020, rana, Update, BHD, Monte Carlo loop coupling Simulations 
                            Reply  Mon Dec 14 11:09:28 2020, Yehonathan, Update, BHD, Monte Carlo loop coupling Simulations MCMC_LANCE_OLTFs.pdfMCMC_LANCE_OLCoupling2DARM.pdf
                               Reply  Mon Jan 11 16:11:51 2021, Yehonathan, Update, BHD, Monte Carlo loop coupling Simulations MC_LANCE_OLTFs.pdf
                                  Reply  Mon Jan 11 19:10:10 2021, rana, Update, BHD, Monte Carlo loop coupling Simulations 
Message ID: 15637     Entry time: Thu Oct 22 11:48:08 2020     In reply to: 15631     Reply to this: 15727
Author: Yehonathan 
Type: Update 
Category: BHD 
Subject: Monte Carlo Simulations 

I found this H1 alog  entry by Izumi confirming that the calibrated channels CAL-CS_* need the same dewhitening filter.

This encouraged me to download the PRCL and MICH data and using Jon's example notebook. I incorporated these noise spectra into the MCMC simulation. The most recent results are attached.

I am still missing:

  • Laser frequency noise
  • Laser RIN
  • Estimation of the LO phase noise
  • Estimation of the BHD breadboard angular noise

Also, now the MCMC repeats a simulation if it doesn't pass the RF PDs test so the number of valid simulations stays the same. I'm still not sure about why the A+ simulations are much more robust to these tests than aLigo simulations.

Attachment 1: MICH_AplusMCMC.pdf  47 kB  Uploaded Thu Oct 22 13:04:34 2020  | Hide | Hide all | Show all
MICH_AplusMCMC.pdf
Attachment 2: PRCL_AplusMCMC.pdf  48 kB  Uploaded Thu Oct 22 13:08:01 2020  | Hide | Hide all | Show all
PRCL_AplusMCMC.pdf
Attachment 3: SRCL_AplusMCMC.pdf  50 kB  Uploaded Thu Oct 22 13:09:19 2020  | Hide | Hide all | Show all
SRCL_AplusMCMC.pdf
Attachment 4: OMC_Comm_AplusMCMC.pdf  51 kB  Uploaded Thu Oct 22 13:10:46 2020  | Hide | Hide all | Show all
OMC_Comm_AplusMCMC.pdf
Attachment 5: OMC_Diff_AplusMCMC.pdf  51 kB  Uploaded Thu Oct 22 13:11:00 2020  | Hide | Hide all | Show all
OMC_Diff_AplusMCMC.pdf
Attachment 6: OMC_Angle_Yaw_AplusMCMC.pdf  51 kB  Uploaded Thu Oct 22 13:12:19 2020  | Show | Hide all | Show all
Attachment 7: OMC_Angle_Pitch_AplusMCMC.pdf  53 kB  Uploaded Thu Oct 22 13:12:32 2020  | Hide | Hide all | Show all
OMC_Angle_Pitch_AplusMCMC.pdf
Attachment 8: Main_Laser_RIN_AplusMCMC.pdf  50 kB  Uploaded Thu Oct 22 13:12:47 2020  | Hide | Hide all | Show all
Main_Laser_RIN_AplusMCMC.pdf
ELOG V3.1.3-