40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Thu Aug 20 00:21:51 2020, gautam, Update, Electronics, First look at HV coil driver  
|
Sun Aug 23 23:36:58 2020, gautam, Update, Electronics, First look at HV coil driver 
|
Wed Aug 26 16:12:25 2020, gautam, Update, Electronics, Test mass coil current requirements
|
Tue Sep 1 15:39:04 2020, gautam, Update, Electronics, HV coil driver oscillations fixed 
|
Thu Oct 22 11:14:47 2020, gautam, Update, Electronics, HV coil driver packaged into 2U chassis  
|
Thu Oct 22 13:04:42 2020, rana, Update, Electronics, HV coil driver packaged into 2U chassis
|
Thu Oct 22 22:01:53 2020, gautam, Update, Electronics, HV coil driver packaged into 2U chassis 
|
Fri Oct 23 09:03:43 2020, anchal, Update, Electronics, HV coil driver packaged into 2U chassis
|
Thu Nov 12 14:55:35 2020, gautam, Update, Electronics, More systematic noise characterization 
|
Thu Nov 12 15:40:42 2020, Koji, Update, Electronics, More systematic noise characterization
|
Mon Nov 16 00:02:34 2020, rana, Update, Electronics, More systematic noise characterization
|
Wed Jan 20 10:13:06 2021, gautam, Update, Electronics, HV Power supply bypassing    
|
Mon Feb 1 12:30:21 2021, gautam, Update, Electronics, More careful characterization  
|
Wed Feb 10 21:14:03 2021, gautam, Update, Electronics, Production version of the HV coil driver tested   
|
Fri Feb 26 16:31:02 2021, gautam, Update, Electronics, Production version of the HV coil driver tested with KEPCO HV supplies
|
Fri Feb 26 20:20:43 2021, Koji, Update, Electronics, Production version of the HV coil driver tested with KEPCO HV supplies
|
Sat Feb 27 17:25:42 2021, gautam, Update, Electronics, Production version of the HV coil driver tested with KEPCO HV supplies
|
Thu May 20 16:56:21 2021, Koji, Update, Electronics, Production version of the HV coil driver tested with KEPCO HV supplies
|
|
Message ID: 15636
Entry time: Thu Oct 22 11:14:47 2020
In reply to: 15552
Reply to this: 15638
15675
|
Author: |
gautam |
Type: |
Update |
Category: |
Electronics |
Subject: |
HV coil driver packaged into 2U chassis |
|
|
I packaged the HV coil driver into a 2U chassis, hoping for better shielding from pickup. There is still considerable excess noise in measurement vs model around 100 Hz, see Attachment #1. The projected displacement noise from this noise contribution is shown in Attachment #2 - I've also plotted the contribution from the 4.5kohm (planned value for fast path series resistance) for comparison. Attachment #3 has some photos of the measurement setup so if someone sees some red flags, please let me know.
- The noise was measured with the output load connected to a 20ohm load resistor, to simulate an OSEM.
- The input signal was driven with an Acromag, to try and mimic the actual operating conditions as closely as possible (although the fast path input was left unconnected).
- The KEPCO switching HV power supplies were used to power the unit.
I've run out of ideas to try and make the measurement cleaner - the presence of the rather prominent power line harmonics suggests that this is still not perfect, but what more shielding can we implement? I have to make the measurement on the circuit side of the 25 kohm series resistor, so I am using some Pomona minigrabbers to clip onto the leg of the wirewound resistor (see photos in Attachment #3), so that's not great maybe, but what's the alternative?
So if this is truly the noise of the circuit, then while it's an improvement on the current situaiton, it's unsatisfying that such a simple circuit can't match the design expectations. But how do we want to proceed? |
|
|
|
|