40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Thu Jul 9 17:12:52 2020, gautam, Update, BHD, In-air BHD 
|
Tue Jul 14 15:29:25 2020, gautam, Update, BHD, In-air BHD - DCPD amplifier noise
|
Wed Jul 15 19:11:40 2020, gautam, Update, BHD, In-air BHD - alignment into OMC
|
Thu Jul 16 01:12:22 2020, gautam, Update, BHD, In-air BHD - preparing the LO path   
|
Sun Jul 19 15:40:15 2020, gautam, Update, BHD, In-air BHD - CDS and wiring summary
|
Wed Jul 29 11:57:59 2020, rana, Update, BHD, In-air BHD - CDS and wiring summary
|
Mon Jul 20 17:55:15 2020, gautam, Update, BHD, In-air BHD - preparing the LO path
|
Tue Jul 21 00:30:24 2020, gautam, Update, BHD, In-air BHD - LO RIN
|
|
Message ID: 15483
Entry time: Wed Jul 15 19:11:40 2020
In reply to: 15464
Reply to this: 15484
15489
|
Author: |
gautam |
Type: |
Update |
Category: |
BHD |
Subject: |
In-air BHD - alignment into OMC |
|
|
I forgot about the pointing - probably we will need another actuator to control the pointing of the AS beam onto the DCPDs. I found a few old PI PZTs (model number is S-320, which is a retired part), one is labelled broken but the others don't indicate a-priori that they are broken. I'll post a more detailed hardware survey later. |