40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Tue May 26 02:15:36 2020, gautam, Update, LSC, Lock acquisition portal entry
|
Tue May 26 02:31:00 2020, gautam, Update, LSC, Lock acquisition sequence
|
Wed May 27 20:14:51 2020, Koji, Update, LSC, Lock acquisition sequence
|
Tue May 26 02:37:19 2020, gautam, Update, LSC, DARM loop measurement and fitting 
|
Tue May 26 03:01:35 2020, gautam, Update, LSC, CARM loop
|
Wed Jun 3 01:46:14 2020, gautam, Update, LSC, CARM loop    
|
Tue May 26 03:06:59 2020, gautam, Update, LSC, PRFPMI sensing matrix 
|
Tue May 26 03:26:58 2020, gautam, Update, LSC, Preliminary noise budget
|
Tue May 26 14:32:44 2020, gautam, Update, LSC, Arm transmission RIN
|
Wed May 27 19:36:33 2020, Koji, Update, LSC, Arm transmission RIN
|
Thu May 28 18:36:45 2020, gautam, Update, LSC, Arm transmission RIN  
|
Fri May 29 00:34:57 2020, rana, Update, LSC, Arm transmission RIN
|
Wed Jun 3 02:14:32 2020, gautam, Update, ASC, PRC ASC improves arm transmission RIN    
|
Fri Jun 19 16:30:09 2020, gautam, Update, ASC, Some thoughts about ASC 
|
Tue Jul 7 14:06:10 2020, gautam, Update, ASC, Some more thoughts about ASC
|
Tue May 26 16:00:06 2020, gautam, Update, LSC, Power buildup diagnostics 
|
Wed May 27 17:41:57 2020, Koji, Update, LSC, Power buildup diagnostics
|
Wed Jun 3 02:08:00 2020, gautam, Update, LSC, Power buildup diagnostics 
|
Wed Jun 3 01:34:53 2020, gautam, Update, LSC, Lock acquisition update portal
|
Wed Jun 3 03:29:26 2020, Koji, Update, LSC, Lock acquisition update portal
|
Wed Jun 3 11:40:56 2020, gautam, Update, LSC, Lock acquisition update portal
|
Wed Jun 3 18:49:47 2020, gautam, Update, LSC, PRG and CARM signal sign   
|
|
Message ID: 15350
Entry time: Tue May 26 02:37:19 2020
In reply to: 15348
|
Author: |
gautam |
Type: |
Update |
Category: |
LSC |
Subject: |
DARM loop measurement and fitting |
|
|
Summary:
In order to estimate the free-running DARM displacement noise, I measured the DARM OLTF using the usual IN1/IN2 prescription. The measured data was then used to fit some model paramters for a loop model that can be used over a larger frequency range.
Details:
- Attachment #1 shows an overlay of the measured and modelled TFs.
- Attachment #2 shows the various components that went into building up this model.
- The digital AA and AI filter coefficients were taken from the RTCDS code.
- The analog AA and AI filter zpks were taken from here and here respectively.
- CDS filters taken from the banks enabled. The 20Hz : 0Hz z:p filter in the CARM_B path is also accounted for, as have the violin-mode notches.
- Pendulum TF is just 1/f^2, the overall scaling is unimportant because it will be fitted (in combination with the overall scaling uncertainty on the DC optical gain), but I used a value of 10 nm/f^2 which should be in the right ballbark.
- The optical gain includes the DARM pole at ~4.5 kHz for this config.
- With all these components, to make the measurement and fit line up, I added two free parameters - an overall gain, and a delay.
- NLSQ minimizer was used to find the best-fit values for these parameters.
- I'm not sure what to make of the relatively large disagreement between measurement and model below 100 Hz - I'm pretty sure I got all the CDS filters included...
- Moreover, I don't have a good explanation for why the best-fit delay is 400 us. One RTCDS clock cycle is onyl 60 us, and even with an extra clock cycle for the RFM transfer, I still can't get up to such a high delay...
In summary, the UGF is ~150 Hz and phase margin is ~30 deg. This loop would probably benefit from some low-pass filter being turned on. |
|
|
|
|