Message ID: 15244     Entry time: Tue Mar 3 18:11:05 2020     In reply to: 15241
Author: Jon 
Type: Summary 
Category: BHD 
Subject: Projected IFO noise budget, post-BHD upgrade 

Revised noise estimates, correcting a couple of factor of 2 and factor of pi errors found in the coil driver noise calculation. Also resolves a strain vs. displacement units confusion using the new pygwinc. Gautam and I have checked these noises against the analytical predictions and believe they are now accurate. Attachments are again:

Attachment 1: Phase quadrature

Attachment 2: Amplitude quadrature

Attachment 3: Comparison to aLIGO design (phase quadrature)

Attachment 1: 40m_phase_quad.pdf  32 kB  | Hide | Hide all
40m_phase_quad.pdf
Attachment 2: 40m_ampl_quad.pdf  32 kB  | Hide | Hide all
40m_ampl_quad.pdf
Attachment 3: 40m_aligo_comp.pdf  26 kB  | Hide | Hide all
40m_aligo_comp.pdf
ELOG V3.1.3-