Message ID: 15237     Entry time: Mon Mar 2 16:14:47 2020
Author: gautam 
Type: Update 
Category: CDS 
Subject: some target directory cleanup 

$TARGET_DIR = /cvs/cds/caltech/target

  • $TARGET_DIR/c1psl and $TARGET_DIR/c1iool0 moved to $TARGET_DIR/preAcromag_oldVME/
  • $TARGET_DIR/c1psl1 moved to $TARGET_DIR/c1psl 
  • $TARGET_DIR/c1psl/*.service and $TARGET_DIR/C1_PSL.cmd modified - i executed :%s/c1psl1/c1psl/g in vim.
  • $TARGET_DIR/preAcromag_oldVME/c1psl/autoBurt.req and $TARGET_DIR/preAcromag_oldVME/c1iool0/autoBurt.req catenated into $TARGET_DIR/c1psl/autoBurt.req. The first snapshot at 16:19 has been verified.

It remains to (Jon is taking care of these)

  • add a line to modbusIOC.service on the new c1psl machine that restores the latest burt snapshot on startup (this necessitated installation of a debian jessie libXp6 package on our debian buster machine because our shared EPICS is soooooooooooooo oooooooold)
  • change the hostname from c1psl1 to c1psl
  • update martian.hosts