Entry  Mon Jan 13 23:30:53 2020, Yehonathan, Summary, PSL, Changes made since Gautam left 
    Reply  Tue Jan 14 20:17:09 2020, gautam, Summary, General, IFO recovery DCerrors.png
       Reply  Wed Jan 15 10:04:19 2020, gautam, Summary, General, POX / POY locking restored singleArms.png
Message ID: 15123     Entry time: Wed Jan 15 10:04:19 2020     In reply to: 15121
Author: gautam 
Type: Summary 
Category: General 
Subject: POX / POY locking restored 

Single arm locking using POX and POY has been restored. After running the dither alignment servos, the TRX/TRY levels are ~0.7. This is consistent with the IMC transmission being ~11000 counts with the AOM 1st order diffracted beam (c.f. 15000 counts with the undiffracted beam).

Quote:

Tomorrow, I'll check the single-arm locking and the ALS system.

Attachment 1: singleArms.png  179 kB  | Hide | Hide all