Message ID: 15054     Entry time: Wed Nov 27 17:51:52 2019
Author: gautam 
Type: Update 
Category: Wiener 
Subject: MCL FF status 

The old MCL filters are not completely useless - I find a factor of ~2 reduction in the MCL RMS when I turn the FF on. It'd be interesting to see how effective the FF is during the periods of enhanced seismic activity we see. I also wonder if this means the old PRC angular FF filters are also working, it'd help locking, tbc with PRMI carrrier...

Update: The PRC angular FF loops also do some good it seems - though the PIT loop probably needs some retuning.

Attachment 1: MCL_FF.pdf  33 kB  | Hide | Hide all
MCL_FF.pdf
Attachment 2: PRC_FF.pdf  62 kB  | Hide | Hide all
PRC_FF.pdf