40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Thu Oct 17 16:49:53 2019, gautam, Update, ASC, PRMI ASC - first pass
|
Tue Oct 22 17:35:30 2019, gautam, Update, ASC, PRMI ASC - first pass 
|
Wed Oct 23 11:14:21 2019, gautam, Update, ASC, PRMI ASC with QPD signals normalized. 
|
|
Message ID: 14985
Entry time: Tue Oct 22 17:35:30 2019
In reply to: 14976
Reply to this: 14988
|
Author: |
gautam |
Type: |
Update |
Category: |
ASC |
Subject: |
PRMI ASC - first pass |
|
|
I made a change to the c1ass model to normalize the PIT and YAW POP QPD outputs by the SUM channel. A saturation block is used to prevent divide-by-zero errors, I set the saturation limits to [1,1e5], since the SUM channel is being recorded as counts right now. Model change is shown in the attached screenshots. I compiled and installed the model. Ran the reboot script to reboot all the vertex FEs to avoid the issue of crashing c1lsc.
Quote: |
I tried implementing a basic PRMI ASC using the POP QPD as a sensor. The POP22 buildup RMS is reduced by a factor of a few. This is just a first attempt, I think the loop shape can be made much better, but the stability of the lock is already pretty impressive. For some past work, see here.
|
|
|
|
|
|