40m QIL Cryo_Lab CTN SUS_Lab CAML OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Thu Aug 8 12:01:12 2019, gautam, Update, IOO, MC1 suspension oddness MC1_suspension.pngMC1_suspension.pdf
    Reply  Mon Aug 12 19:58:23 2019, gautam, Update, IOO, MC1 suspension oddness 
Message ID: 14842     Entry time: Mon Aug 12 19:58:23 2019     In reply to: 14836
Author: gautam 
Type: Update 
Category: IOO 
Subject: MC1 suspension oddness 

Repair plan:

  1. Get "spare" satellite box working --- Chub
    • According to elog14441, this box has flaky connectors which probably need to be remade
  2. Re-make the 64-pin IDC crimped connection on the cable from the coil driver board to sat. box, at the Satellite box end --- Chub and gautam

Any other ideas? The problem persists and it's annoying that the IMC cannot be locked.

ELOG V3.1.3-