Entry  Thu May 23 15:37:30 2019, Milind, Update, Cameras, Simulation enhancements and performance of contour detection 6x
    Reply  Sat May 25 20:29:08 2019, Milind, Update, Cameras, Simulation enhancements and performance of contour detection residue_normalised_x.pdfresidue_normalised_x.pdfresidue_normalised_x.pdfpredicted_motion_x.pdfnormalised_comparison_y.pdf
       Reply  Wed Jun 12 22:02:04 2019, Milind, Update, Cameras, Simulation enhancements  simulated_motion0.mp4simulated_motion0.mp4simulated_motion0.mp4
          Reply  Mon Jun 17 14:36:13 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking 
             Reply  Tue Jun 18 22:54:59 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking 
                Reply  Tue Jun 25 00:25:47 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking 8x
                   Reply  Tue Jun 25 22:14:10 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking 
                      Reply  Thu Jun 27 20:48:22 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking readme.txtframe0.pdfLearning_curves.pngMotion.png
                         Reply  Thu Jul 4 18:19:08 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking Motion.pdfError.pdfLearning_curves.pdf
                            Reply  Mon Jul 8 17:52:30 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking Motion.pdf
                               Reply  Tue Jul 9 22:13:26 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking predicted_motion_first.pdfpcdev5_time.png
                                  Reply  Wed Jul 10 22:32:38 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking 
                               Reply  Mon Jul 15 14:09:07 2019, Milind, Update, Cameras, CNN LSTM for beam tracking cnn-lstm.pngfft_yaw.pdfyaw_motion.pdf
                                  Reply  Fri Jul 19 16:47:06 2019, Milind, Update, Cameras, CNNs for beam tracking || Analysis of results 7x
                                     Reply  Sat Jul 20 12:16:39 2019, gautam, Update, Cameras, CNNs for beam tracking || Analysis of results 
                                        Reply  Sat Jul 20 14:43:45 2019, Milind, Update, Cameras, CNNs for beam tracking || Analysis of results frame0.pdfsubplot_yaw_test.pdfintensity_histogram.mp4network2.pdf
                                           Reply  Wed Jul 24 20:05:47 2019, Milind, Update, Cameras, CNNs for beam tracking || Tales of desperation saturation_percentage.pdf
                   Reply  Thu Jul 25 00:26:47 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking centroid.pdfsubplot_yaw_test.pdf
          Reply  Mon Jun 17 22:19:04 2019, Milind, Update, Computer Scripts / Programs, PMC autolocker 
             Reply  Mon Jul 1 20:18:01 2019, Milind, Update, Computer Scripts / Programs, PMC autolocker 
                Reply  Tue Jul 2 12:30:44 2019, Milind, Update, Computer Scripts / Programs, PMC autolocker 
                   Reply  Sun Jul 7 17:54:34 2019, Milind, Update, Computer Scripts / Programs, PMC autolocker 
          Reply  Tue Jun 25 23:52:37 2019, Milind, Update, Cameras, Simulation enhancements  
             Reply  Mon Jul 1 20:11:34 2019, Milind, Update, Cameras, Simulation enhancements  
Message ID: 14809     Entry time: Thu Jul 25 00:26:47 2019     In reply to: 14694
Author: Milind 
Type: Update 
Category: Cameras 
Subject: Convolutional neural networks for beam tracking 

Somehow I never got around to doing the pixel sum thing for the new real data from the GigE. Since I have to do it for the presentation, I'm putting up the results here anyway. I've normalized this and computed the SNR with the true readings.

SNR = (power in true readings)/ (power in error signal between true and predicted values)

Attachment #2 is SNR of best performing CNN for comparison.

Attachment 1: centroid.pdf  32 kB  Uploaded Thu Jul 25 01:29:32 2019  | Hide | Hide all
centroid.pdf
Attachment 2: subplot_yaw_test.pdf  27 kB  Uploaded Thu Jul 25 04:00:10 2019  | Hide | Hide all
subplot_yaw_test.pdf
ELOG V3.1.3-