40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Thu May 23 15:37:30 2019, Milind, Update, Cameras, Simulation enhancements and performance of contour detection 6x
    Reply  Sat May 25 20:29:08 2019, Milind, Update, Cameras, Simulation enhancements and performance of contour detection residue_normalised_x.pdfresidue_normalised_x.pdfresidue_normalised_x.pdfpredicted_motion_x.pdfnormalised_comparison_y.pdf
       Reply  Wed Jun 12 22:02:04 2019, Milind, Update, Cameras, Simulation enhancements  simulated_motion0.mp4simulated_motion0.mp4simulated_motion0.mp4
          Reply  Mon Jun 17 14:36:13 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking 
             Reply  Tue Jun 18 22:54:59 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking 
                Reply  Tue Jun 25 00:25:47 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking 8x
                   Reply  Tue Jun 25 22:14:10 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking 
                      Reply  Thu Jun 27 20:48:22 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking readme.txtframe0.pdfLearning_curves.pngMotion.png
                         Reply  Thu Jul 4 18:19:08 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking Motion.pdfError.pdfLearning_curves.pdf
                            Reply  Mon Jul 8 17:52:30 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking Motion.pdf
                               Reply  Tue Jul 9 22:13:26 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking predicted_motion_first.pdfpcdev5_time.png
                                  Reply  Wed Jul 10 22:32:38 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking 
                               Reply  Mon Jul 15 14:09:07 2019, Milind, Update, Cameras, CNN LSTM for beam tracking cnn-lstm.pngfft_yaw.pdfyaw_motion.pdf
                                  Reply  Fri Jul 19 16:47:06 2019, Milind, Update, Cameras, CNNs for beam tracking || Analysis of results 7x
                                     Reply  Sat Jul 20 12:16:39 2019, gautam, Update, Cameras, CNNs for beam tracking || Analysis of results 
                                        Reply  Sat Jul 20 14:43:45 2019, Milind, Update, Cameras, CNNs for beam tracking || Analysis of results frame0.pdfsubplot_yaw_test.pdfintensity_histogram.mp4network2.pdf
                                           Reply  Wed Jul 24 20:05:47 2019, Milind, Update, Cameras, CNNs for beam tracking || Tales of desperation saturation_percentage.pdf
                   Reply  Thu Jul 25 00:26:47 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking centroid.pdfsubplot_yaw_test.pdf
          Reply  Mon Jun 17 22:19:04 2019, Milind, Update, Computer Scripts / Programs, PMC autolocker 
             Reply  Mon Jul 1 20:18:01 2019, Milind, Update, Computer Scripts / Programs, PMC autolocker 
                Reply  Tue Jul 2 12:30:44 2019, Milind, Update, Computer Scripts / Programs, PMC autolocker 
                   Reply  Sun Jul 7 17:54:34 2019, Milind, Update, Computer Scripts / Programs, PMC autolocker 
          Reply  Tue Jun 25 23:52:37 2019, Milind, Update, Cameras, Simulation enhancements  
             Reply  Mon Jul 1 20:11:34 2019, Milind, Update, Cameras, Simulation enhancements  
Message ID: 14734     Entry time: Mon Jul 8 17:52:30 2019     In reply to: 14726     Reply to this: 14741   14760
Author: Milind 
Type: Update 
Category: Cameras 
Subject: Convolutional neural networks for beam tracking 

After the two earthquakes, I collected some data by dithering the optic and recording the QPD readings. Today, I set up scripts to process the data and then train networks on this data. I have pushed all the code to github. I attempted to train a bunch of networks on the new data to test if the code was alright but realised quickly that, training on my local machine is not feasilble at all as training for 10 epochs took roughly 6 minutes. Therefore, I have placed a request for access to the cluster and am waiting for a reply. I will now set up a bunch of experiments to tune hyperparameters for this data and see what the results are.

Trainng networks with memory

I set up a network to handle input volumes (stacks of frames) instead of individual frames. It still uses 2D convolution and not 3D convolution. I am currently training on the new data. However, I was curious to see if it would provide any improved performance over the results I put up in the previous elog. After a bit of hyperparameter tuning, I did get some decent results which I have attached below. However, this is for Pooja's old data which makes them, ah, not so relevant. Also, this testing isn't truly representative because the test data isn't entirely new to the network. I am going to train this network on the new data now with the following objectives (in the following steps):

  1. Train on data recorded at one frequency, generalize/ test on unseen data of the same frequency, large amplitude of motion
  2. Train on data recorded at one frequency, generallize/ test on unseen data of a different frequency, large amplitude of motion
  3. Train on data recorded at one frequency, generalize/ test on unseen data of  same/ different frequency, small amplitude of motion
  4. Train on data at different frequencies and generalize/ test on data with a mixture of frequencies at small amplitudes - Gautam pointed out that the network would truly be superb (good?) if we can just predict the QPD output from the video of the beam spot when nothing is being shaken.

I hope this looks alright? Rana also suggested I try LSTMs today. I'll maybe code it up tomorrow. What I have in mind- A conv layer encoder, flatten, followed by an LSTM layer (why not plain RNNs? well LSTMs handle vanishing gradients, so why the hassle).

Quote:

The quoted elog has figures which indicate that the network did not learn (train or generalize) on the used data. This is a scary thing as (in my experience) it indicates that something is fundamentally wrong with either the data or model and learning will not happen despite how hyperparameters are tuned. To check this, I ran the training experiment for nearly 25 hyperparameter settings (results here)with the old data and was able to successfully overfit the data. Why is this progress? Well, we know that we are on the right track and the task is to reduce overfitting. Whether, that will happen through more hyperparameter tuning, data collection or augmentation remains to be seen. See attachments for more details. 

Why is the fit so perfect at the start and bad later? Well, that's because the first 90% of the test data is  the training data I overfit to and the latter the validation data that the network has not generalized well to.