40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Mon Jun 3 16:46:31 2019, gautam, Update, IOO, IMC not locking PCdrive_RMS.png
    Reply  Tue Jun 4 10:56:31 2019, gautam, Update, IOO, IMC diagnostics IMCdiag.pdf
       Reply  Thu Jun 6 22:11:53 2019, Koji, Update, IOO, IMC diagnostics 
          Reply  Thu Jun 13 18:01:18 2019, aaron, Update, IOO, IMC diagnostics 
             Reply  Fri Jun 14 13:10:00 2019, aaron, Update, IOO, IMC diagnostics 
                Reply  Mon Jun 17 12:37:16 2019, aaron, Update, IOO, IMC diagnostics 
                   Reply  Tue Jun 18 20:35:07 2019, aaron, Update, IOO, IMC diagnostics 
                      Reply  Wed Jun 19 19:12:51 2019, aaron, Update, IOO, IMC diagnostics PMC_Error_Spectrum.pdfPDH_signal.pdfPDH_signal_full.pdf
                         Reply  Mon Jun 24 15:49:05 2019, aaron, Update, IOO, IMC diagnostics sweep_config_updated.png
                            Reply  Tue Jul 2 19:36:18 2019, aaron, Update, IOO, IMC diagnostics PDH_error.pdfPMC_Error_Spectrum.pdf
          Reply  Fri Jun 21 19:36:26 2019, Koji, Update, IOO, IMC diagnostics IMC_error.pdf
             Reply  Sun Jun 23 08:09:53 2019, gautam, Update, IOO, NPRO diagnostics consolidatedOscopeScreenCaps.pdfRINcomp.pdfPLL_OLTF.pdfPLLnoise.pdf
                Reply  Sun Jun 23 09:36:32 2019, gautam, Update, IOO, IMC is locking normally again PMCdiag.pdf
                   Reply  Sun Jun 23 14:43:14 2019, Koji, Update, IOO, IMC is locking normally again 
                   Reply  Mon Jun 24 08:12:10 2019, gautam, Update, IOO, IMC is locking normally again IMCdutycycle.png
                      Reply  Mon Jun 24 11:48:35 2019, gautam, Update, IOO, IMC in-loop error spectra and OLTF IMCfreqNoise.pdfIMC_OLTF.pdfIMC_CMboard.jpg
Message ID: 14690     Entry time: Mon Jun 24 08:12:10 2019     In reply to: 14688     Reply to this: 14691
Author: gautam 
Type: Update 
Category: IOO 
Subject: IMC is locking normally again 

Over the last 24 hours, the IMC autolocker was able to keep the MC locked ~60% of the time. This is not particularly good, but is an improvement on ~2 weeks ago when the IMC couldn't be locked.

There are two periods, which I've indicated by vertical cursors, between which the autolocker was doing something strange - usually this kind of trend is caused by one or more of the VME crates being unresponsive and the autolocker gets stuck, but I confirmed that both c1psl and c1iool0 are telnet-able. So I conclude that the stability and reliability of the IMC loop is still not as good as it used to be.

Note also that while the PC drive RMS level mostly hovers around 1 V, there are several excursions above that level. This in itself isn't a new phenomenon. I will do some more characterization by measuring the in-loop error signal spectrum and maybe the OLTF of the IMC locking loop.

Quote:
 

Let' see how stable or otherwise the config is. I must've jiggled some poor cable connection back into a good spot while working on the PSL table? Or the NPRO decided to be less noisy on Sunday.

Attachment 1: IMCdutycycle.png  274 kB  Uploaded Mon Jun 24 09:15:09 2019  | Hide | Hide all
IMCdutycycle.png
ELOG V3.1.3-