Entry  Mon Apr 1 12:01:52 2019, Jon, Update, CDS,  
    Reply  Mon Apr 1 22:33:00 2019, gautam, Update, CDS, ITMY freed 
       Reply  Tue Apr 2 15:02:53 2019, Jon, Update, CDS, ITMY freed 
Message ID: 14508     Entry time: Tue Apr 2 15:02:53 2019     In reply to: 14506
Author: Jon 
Type: Update 
Category: CDS 
Subject: ITMY freed 

blushI renamed all channels on c1susaux2 from "C1:SUS-..." to "C1:SUS2-..." to avoid contention. When the new system is ready to install, those channel names can be reverted with a quick search-and-replace edit.

Quote:

While doing this work, I noticed several errors corresponding to EPICS channel conflicts. Turns out the c1susaux2 EPICS server was left running, and the MEDM screens (and possibly several scripts) were confused. There has to be some other way of testing the new crate, on an isolated network or something - please do not leave the modbus service running as it potentially interferes with normal IFO operation. For good measure, I stopped the process and shut down the machine since I saw nothing in the elog about any running tests.