Sun Aug 5 13:28:43 2018, gautam, Update, CDS, c1lsc flaky
|
Mon Aug 6 00:26:21 2018, gautam, Update, CDS, More CDS woes
|
Mon Aug 6 14:38:38 2018, gautam, Update, CDS, More CDS woes 
|
Mon Aug 6 19:49:09 2018, gautam, Update, CDS, More CDS woes
|
Tue Aug 7 11:30:46 2018, gautam, Update, CDS, More CDS woes
|
Tue Aug 7 22:28:23 2018, gautam, Update, CDS, More CDS woes
|
Wed Aug 8 23:03:42 2018, gautam, Update, CDS, c1lsc model started
|
Thu Aug 9 12:31:13 2018, gautam, Update, CDS, CDS status update
|
Wed Aug 15 21:27:47 2018, gautam, Update, CDS, CDS status update
|
Tue Sep 4 10:14:11 2018, gautam, Update, CDS, CDS status update
|
Wed Sep 5 10:59:23 2018, wgautam, Update, CDS, CDS status update
|
Thu Sep 6 14:21:26 2018, gautam, Update, CDS, ADC replacement in c1lsc expansion chassis
|
Fri Sep 7 12:35:14 2018, gautam, Update, CDS, ADC replacement in c1lsc expansion chassis
|
Mon Sep 10 12:44:48 2018, Jon, Update, CDS, ADC replacement in c1lsc expansion chassis
|
Thu Sep 20 11:29:04 2018, gautam, Update, CDS, New PCIe fiber housed 
|
Thu Sep 20 16:19:04 2018, gautam, Update, CDS, New PCIe fiber install postponed to tomorrow
|
Fri Sep 21 16:46:38 2018, gautam, Update, CDS, New PCIe fiber installed and routed 
|
|
Message ID: 14136
Entry time: Mon Aug 6 00:26:21 2018
In reply to: 14133
Reply to this: 14139
|
Author: |
gautam |
Type: |
Update |
Category: |
CDS |
Subject: |
More CDS woes |
|
|
I spent most of today fighting various CDS errors.
- I rebooted c1lsc around 3pm, my goal was to try and do some vertex locking and figure out what the implications were of having only ~30% power we used to have at the AS port.
- Shortly afterwards (~4pm), c1lsc crashed.
- Using the reboot script, I was able to bring everything back up. But the DC lights on c1sus models were all red, and a 0x4000 error was being reported.
- This error is indicative of some timing issue, but all the usual tricks (reboot vertex FEs in various order, restart the mx_streams etc) didn't clear this error.
- I checked the Tempus GPS unit, that didn't report any obvious problems (i.e. front display was showing the correct UTC time).
- Finally, I decided to shut down all watchdogs, soft reboot all the FEs, soft reboot FB, power cycle all expansion chassis.
- This seems to have done the trick - I'm leaving c1oaf disabled for now.
- The remaining red indicators are due to c1dnn and c1oaf being disabled.
Let's see how stable this configuration is. Onto some locking now... |
|
|