Subject: Update in developing neural networks 

Aim: To develop a neural network that resolves mirror motion from video.

I had created a python code to find the combination of hyperparameters that trains the neural network. The code (nn_hyperparam_opt.py) is present in the github repo. It's running in cluster since a few days. In the meanwhile I had just tried some combination of hyperparameters.

These give a low loss value of approximately 1e-5 but there is a large error bar for loss value since it fluctuates a lot even after 1500 epochs. This is unclear.

Input: 64*64 image frames of simulated video by applying beam motion sine wave of frequency 0.2Hz and at 10 frames per sec. This input data is given as an hdf5 file.

Train : 100 cycles,  Test: 300 cycles, Optimizer = Nadam (learning rate = 0.001)

Model topology:

                    256       ->      128    ->       1

Activation :        selu     selu           linear

Case 1: batch size = 48, epochs = 1000, loss function = mean squared error

Plots of output predicted by neural network (NN) & input signal has been shown in 1st graph & variation in loss value with epochs in 2nd graph.

Case 2: batch size = 32, epochs = 1500, loss function = mean squared logarithmic error

Plots of output predicted by neural network (NN) & input signal has been shown in 3rd graph & variation in loss value with epochs in 4th graph.

 

 

 

Attachment 1: graphs.pdf  1.939 MB  Uploaded Fri Jul 13 15:07:33 2018  | Hide | Hide all
graphs.pdf graphs.pdf graphs.pdf graphs.pdf