Mon Jun 11 11:45:13 2018, keerthana , Update, elog, Comparison of the analytical and finesse values of TMS and FSR.
|
Mon Jun 11 18:10:51 2018, Koji , Update, elog, Comparison of the analytical and finesse values of TMS and FSR.
|
Mon Jun 11 19:16:49 2018, keerthana, Update, elog, Comparison of the analytical and finesse values of TMS and FSR.
|
Mon Jun 11 22:05:03 2018, Koji, Update, elog, Comparison of the analytical and finesse values of TMS and FSR.
|
Mon Jun 11 22:18:18 2018, keerthana, Update, elog, Comparison of the analytical and finesse values of TMS and FSR.
|
|
Message ID: 13941
Entry time: Mon Jun 11 18:10:51 2018
In reply to: 13938
Reply to this: 13943
|
Author: |
Koji |
Type: |
Update |
Category: |
elog |
Subject: |
Comparison of the analytical and finesse values of TMS and FSR. |
|
|
Hmm? What is the definition of the percentage error? I don't obtain these numbers from the given values.
And how was the finesse value obtained from the simulation result? Then what is the frequency resolution used in Finesse simulation? |