As of now, I have made the codes needed to sweep the marconi frequency for taking the cavity scan data, the photo diode at the y-end is conected to the spectrum analyser already and I also have the finesse simulation of the Ideal Fabry-perot cavity. By seeing my last elog entry, Gautam suggested me that I need to take a different approach for estimating the FSR and TMS value from the Finesse graph. That is, by using least square fit models. Now I am trying to do that and get a better estimate of the error values. Based on my understanding I am dividing this project into various tasks.
1. Getting a better estimate of the error value by using least square fits. Also plotting a graph of frequency Vs mode number and finding the value of Free Spectral Range from its slop.
2. Inserting zernike polynomials to the Finesse simulation and with the help of least square fit, plotting the graph of frequency Vs mode number. Understanding the shifts from the Ideal graph we obtained from step 1. Using this data, plotting the phase map corresponding to this.
3. Repeating step 2 by taking different zernike polynomials and creating a data base which will be useful for the analysis of the real data. This will also prepare me to do the fitting models easily.
4. Collecting data from the IFO and applying these fitting models to it. Finding the set of zernike polynomials which are similar to the actual fugure error of the mirror. Plotting the Phase map corresponding to those zernike polynomials.
If you feel that there is some mistake in the steps, please correct me. It will be really helpful! |