40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Mon Mar 19 23:44:00 2018, gautam, Update, IOO, IMC loop checkup IMC_RF_noise.pdfIMC_OLTF_20180320.pdf
    Reply  Tue Mar 20 16:53:03 2018, gautam, Update, IOO, IMC loop checkup IMC_RF_noise.pdf
       Reply  Tue Mar 20 21:08:03 2018, gautam, Update, IOO, IMC loop checkup 
          Reply  Tue Mar 20 22:44:45 2018, gautam, Update, IOO, IMC loop checkup 
             Reply  Wed Mar 21 15:52:45 2018, gautam, Update, IOO, MC error point calibration IMC_PDHdisc_20180321.pdfIMC_PDHdisc785_20180321.pdfIMC_oscope.pdf
                Reply  Wed Mar 21 17:31:21 2018, gautam, Update, IOO, MC error point calibration IMC_RF_noise_calib.pdf
                   Reply  Wed Mar 21 21:13:44 2018, gautam, Update, IOO, IMC noise budget IMC_RF_noise_calib.pdf
                      Reply  Tue Mar 27 01:39:44 2018, gautam, Update, IOO, PSL noise eater was off IR_ALS_20180326.pdf
                         Reply  Tue Mar 27 19:32:03 2018, arijit, Update, IOO, PSL noise eater was off MCREFL_TF.pdfMCREFL_SPECTRUM.pdf
                            Reply  Tue Mar 27 23:37:35 2018, gautam, Update, IOO, MC REFL PD removed IMG_6955.JPG
                               Reply  Wed Mar 28 21:31:39 2018, gautam, Update, IOO, MC REFL PD removed 
                            Reply  Wed Mar 28 21:47:37 2018, arijit, Update, IOO, MCREFL_PD Optical response measurement LISO_fit_with_info.pdfLISO_fit.zip
                               Reply  Thu Mar 29 17:57:36 2018, arijit, Update, IOO, MCREFL_PD Optical response measurement NOISE_EATER_On_OFF.pdf
                                  Reply  Fri Mar 30 06:14:31 2018, rana, Update, IOO, MCREFL_PD Optical response measurement 
                                     Reply  Fri Mar 30 22:37:36 2018, Kevin, Update, IOO, MCREFL_PD Optical response measurement REFLPD_DemodBoard.pdf
                      Reply  Thu Apr 5 04:36:56 2018, Kevin, Update, IOO, Coil driver noise MC3.pdfMC2.pdfCoilDriver.pdf
                         Reply  Thu Apr 5 12:13:18 2018, Koji, Update, IOO, Coil driver noise 
                            Reply  Fri Apr 6 21:39:09 2018, gautam, Update, IOO, MC2 suspension health checkup MC2_Freeswinging.pdf
                               Reply  Mon Apr 9 18:46:03 2018, gautam, Update, IOO, Further debugging MC_Freeswinging.pdfIMC_NB_20180409.pdf
                                  Reply  Tue Apr 10 14:28:44 2018, gautam, Update, IOO, Further debugging 
                                     Reply  Wed Apr 11 01:34:31 2018, gautam, Update, IOO, Activities today 
                                        Reply  Thu Apr 12 18:12:49 2018, gautam, Update, ALS, NPRO channels hijacked IR_ALS_20180412.pdfBeatMouthDrift.pngETMX_20180416.jpg
                                           Reply  Fri Apr 13 11:02:41 2018, gautam, Update, ALS, EX fiber polarization drift EX_pol_drift.png
                                              Reply  Fri Apr 13 17:56:26 2018, gautam, Update, ALS, Fibers switched out 
                                                 Reply  Sat Apr 14 14:42:09 2018, gautam, Update, ALS, Fibers switched out PSLdrift.png
                                                    Reply  Tue Apr 17 14:08:29 2018, gautam, Update, ALS, Fibers switched out PSL_fluctuations.png
                                                       Reply  Fri Apr 20 00:26:34 2018, gautam, Update, ALS, Fibers switched out 
                                                          Reply  Sat Apr 21 20:25:12 2018, gautam, Update, ALS, PSL fiber pickoff status PSL-beatMouthPickoff.png
                                  Reply  Thu Apr 19 00:03:51 2018, gautam, Update, IOO, More IMC NBing IMC_NB_20180409.pdfIMC_coils_20180418.pdf
                                     Reply  Thu Apr 19 17:15:35 2018, gautam, Update, IOO, More IMC NBing IMC_NB_20180419.pdfIMC_coilDriverNoises_20180419.pdf
                                        Reply  Sun May 20 23:43:50 2018, gautam, Update, IOO, Coil driver noise re-measurement MC1_coilDriver.pdfMC2_coilDriver.pdfMC3_coilDriver.pdfMC_coilDriverNoises.tgzActuationChainNoiseMeas.pdf
                                           Reply  Tue May 22 17:26:25 2018, gautam, Update, IOO, MC1 Coil Driver pulled out 
                                              Reply  Tue May 22 23:28:01 2018, gautam, Update, IOO, MC1 Coil Driver pulled out 
                                                 Reply  Wed May 23 17:58:48 2018, gautam, Update, IOO, MC1 Coil Driver pulled out MC1_monitorTF.pngMC1_ULnoise.pdf
                                                    Reply  Wed May 30 10:17:46 2018, gautam, Update, IOO, MC1 Coil Driver pulled out EM_pickup.pdfcoilDriverNoiseComparison.pdf
                            Reply  Fri Apr 6 22:23:53 2018, Kevin, Update, IOO, Coil driver noise MC2_coil_driver.pdf
Message ID: 13883     Entry time: Wed May 23 17:58:48 2018     In reply to: 13880     Reply to this: 13896
Author: gautam 
Type: Update 
Category: IOO 
Subject: MC1 Coil Driver pulled out 
  • Marked up schematic + photo post changes uploaded to DCC page.
  • There was a capacitor in the DAQ monitor path making a 8kHz corner that I now removed (since the main point of this front panel HPF monitor point is to facilitate easy coil driver noise debugging, and I wanted to be able to use the SR785 out to high frequencies without accounting for an additional low pass). Transfer function from front panel LEMO input to front panel LEMO monitor is shown in Attachment #1.
  • Voltage noise measured at DB25 output (with the help of a breakout cable and SR560 G=100) with front panel LEMO input terminated to 50ohm, Bias input grounded, and pin1 of U21A grounded (i.e. watchdog enabled state) is shown in Attachment #2. This measurement was taken on the electronics bench.
  • Inside the lab (i.e. coil driver board plugged into eurocrate), the noise measured in the same way looks identical to what was measured in elog13870.
  • I tried repeating the measurement by powering the board using an bench power supply and grounding the bias input voltage near 1X6, and the strange noise profile persists. So this supports the hypothesis that some kind of environmental pickup is causing this noise profile. Needs more investigation. 

In any case, if it is indeed true that the optic sees this current noise, the place to make the measurement is probably the Sat. Box. Who knows what the pickup is over the ~15m of cable from 1X6 to the optic.

Quote:

Detailed report + photos to follow

 

Attachment 1: MC1_monitorTF.png  136 kB  Uploaded Wed May 23 19:10:33 2018  | Hide | Hide all
MC1_monitorTF.png
Attachment 2: MC1_ULnoise.pdf  214 kB  Uploaded Wed May 23 19:20:23 2018  | Hide | Hide all
MC1_ULnoise.pdf
ELOG V3.1.3-