Sun Apr 29 22:53:06 2018, gautam, Update, General, DARM actuation estimate
|
Tue May 1 19:37:50 2018, gautam, Update, General, DARM actuation estimate 
|
Mon May 7 16:23:06 2018, gautam, Update, General, DARM actuation estimate  
|
Mon May 7 20:01:14 2018, Rorpheus, Update, General, Use anti-dewhitening + show CARMA/DARMA
|
Thu May 10 14:13:22 2018, gautam, Update, General, More refinement of DARM control signal projection  
|
Fri May 11 13:58:42 2018, rana, Update, General, More refinement of DARM control signal projection
|
Fri May 11 19:02:52 2018, gautam, Update, General, More refinement of DARM control signal projection    
|
Sat May 12 10:02:03 2018, rana, Update, General, More refinement of DARM control signal projection
|
Sun May 20 17:43:01 2018, rana, Update, Electronics, How to choose resistors
|
Mon May 14 18:58:32 2018, Kevin, Update, PonderSqueeze, Squeezing with no SRM  
|
Tue Oct 2 23:57:16 2018, gautam, Update, PonderSqueeze, Squeezing scenarios
|
Tue May 15 21:56:57 2018, gautam, Update, General, Stack measurement setup decommissioned
|
Thu May 17 09:14:38 2018, Steve, Update, General, Stack measurement setup decommissioned 
|
|
Message ID: 13836
Entry time: Sat May 12 10:02:03 2018
In reply to: 13835
Reply to this: 13869
|
Author: |
rana |
Type: |
Update |
Category: |
General |
Subject: |
More refinement of DARM control signal projection |
|
|
Good question! I've never calculated what the resonance frequency would be if had an inductive resistor with our cable capacitance (~50 pF/m I guess). |