40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Fri May 4 13:24:56 2018, Jon Richardson, Configuration, Electronics, AUX-PSL PLL Implementation & Characterization 
|
Fri May 4 19:06:28 2018, rana, Configuration, Electronics, AUX-PSL PLL Implementation & Characterization
|
Tue May 15 20:51:27 2018, gautam, Configuration, Electronics, Making PLL setup more permanent
|
Wed May 16 18:52:50 2018, gautam, Configuration, Electronics, PLL mysteries solved  
|
|
Message ID: 13816
Entry time: Fri May 4 19:06:28 2018
In reply to: 13814
Reply to this: 13845
|
Author: |
rana |
Type: |
Configuration |
Category: |
Electronics |
Subject: |
AUX-PSL PLL Implementation & Characterization |
|
|
this doesn't make much sense to me; the phase to frequency conversion (mixer-demod to PZT ) should give us a 1/f loop as Johannes mentioned in the meeting. That doesn't agree with your loop shape.
How about give us some more details of the setup including photos and signal/power levels? And maybe measure the LB1005 TF by itself to find out what's wrong with the loop. |