40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Thu Jan 4 12:46:27 2018, gautam, Update, ALS, Fiber ALS assay FiberALS.pdfFiberALS.svg.zip
    Reply  Thu Jan 11 14:22:40 2018, gautam, Update, ALS, Fiber ALS assay 
       Reply  Thu Jan 11 20:51:20 2018, gautam, Update, ALS, Fiber ALS assay IMG_5112.JPG
          Reply  Tue Jan 16 21:50:53 2018, gautam, Update, ALS, Fiber ALS assay 
             Reply  Thu Jan 18 00:35:00 2018, gautam, Update, ALS, Fiber ALS assay IR_ALS_20180118.pdfC2B4C1DD-6528-4067-9C13-6BD248629AD6.MOV
                Reply  Fri Jan 19 11:34:21 2018, gautam, Update, ALS, Fiber ALS assay IR_ALS_20180119.pdf
                   Reply  Fri Jan 19 23:04:11 2018, gautam, Update, ALS, Fiber ALS assay 
                      Reply  Wed Jan 24 00:33:31 2018, gautam, Update, ALS, Fiber ALS assay IMG_6866.JPG
                         Reply  Wed Jan 24 10:45:14 2018, gautam, Update, ALS, Fiber ALS assay 
                         Reply  Thu Jan 25 23:59:14 2018, gautam, Update, ALS, Fiber ALS assay 
                            Reply  Fri Jan 26 20:03:09 2018, gautam, Update, ALS, Fiber ALS assay 
                               Reply  Wed Jan 31 15:45:22 2018, gautam, Update, ALS, Fiber ALS assay IMG_6875.JPG
                                  Reply  Wed Jan 31 16:29:42 2018, gautam, Update, ALS, Modulation depths PMCmodDepth.pdfXPDH.pdf
                                  Reply  Wed Jan 31 16:33:53 2018, gautam, Update, ALS, ALS electronics at LSC rack 
                                     Reply  Wed Jan 31 22:32:11 2018, gautam, Update, ALS, ALS signal chain + power budget FiberALS_PowerBudget.pdfpreampProposed.pdf
                                        Reply  Thu Feb 1 01:24:56 2018, gautam, Update, ALS, D0902745 revamp underway PSLinterlock.png
                                           Reply  Fri Feb 2 00:26:34 2018, gautam, Update, ALS, D0902745 revamp underway 
                                              Reply  Fri Feb 2 13:16:55 2018, gautam, Update, ALS, ALS signals whitening switching ALS_whitening_switching.pdfALS_whitening_switching_works.pdf
                                                 Reply  Mon Feb 5 14:11:01 2018, gautam, Update, ALS, Huge harmonics in ALS channels ALSpowerlineHarmonics.pdf2A1B3AC4-4059-416A-AD88-8AB0431D7A55.jpeg
                                                    Reply  Mon Feb 5 22:57:28 2018, gautam, Update, ALS, Huge harmonics in ALS channels 
                                                       Reply  Tue Feb 6 11:13:26 2018, gautam, Update, ALS, Possible source of ground loop identified A68AF89C-E8A9-416D-BBD2-A1AD0A51E0B5.jpeg
                                                          Reply  Tue Feb 6 22:55:51 2018, gautam, Update, ALS, Possible source of ground loop identified 
                                                       Reply  Thu Feb 8 00:33:20 2018, gautam, Update, ALS, D990694 characterization / THD measurement plan D990694THD_trial.pdf
                                                          Reply  Thu Feb 8 01:27:16 2018, Koji, Update, ALS, D990694 characterization / THD measurement plan 
                                                          Reply  Fri Feb 9 13:37:44 2018, gautam, Update, ALS, THD measurement trial THD_trial.pdf
                                                       Reply  Thu Feb 8 12:00:09 2018, gautam, Update, ALS, D990694 is NOT differential receiving 
                                                          Reply  Thu Feb 8 13:13:14 2018, gautam, Update, ALS, D990694 pulled out IMG_5131.JPGIMG_5133.JPGD990694-B_cuttingPlan.pdf
                                                             Reply  Thu Feb 8 18:10:36 2018, gautam, Update, ALS, D990694 pulled out 
                                              Reply  Wed Feb 7 15:51:15 2018, gautam, Update, ALS, D0902745 revamp complete 6613CD37-5014-44AE-B1FE-6F6A8137DF62.jpeg
                                                 Reply  Fri Feb 16 01:34:40 2018, gautam, Update, ALS, D0902745 in-situ testing BeatMouthX_20180216.pdfIMG_5134.JPG
                                                    Reply  Tue Feb 20 23:08:27 2018, gautam, Update, ALS, D0902745 in-situ testing BeatMouthX_20180220_diffOut.pdf
                                                       Reply  Thu Feb 22 00:09:11 2018, gautam, Update, ALS, D0902745 in-situ testing daughterBoard_TF.pdfdaughterBoard_noise.pdfIMG_6906.JPG
                                                          Reply  Sun Feb 25 00:03:12 2018, gautam, Update, ALS, Daughter board prototyping schematic.pdfdaughterBoard_TF.pdfdaughterBoard_noise.pdfTEK00000.PNGdaughterBoard_noise.pdf
                                                             Reply  Mon Feb 26 20:55:56 2018, rana, Update, ALS, Daughter board prototyping 
                                                                Reply  Tue Feb 27 21:10:45 2018, gautam, Update, ALS, Daughter board testing IMG_6912.JPGIMG_6913.JPGIMG_6914.JPG
                                                                   Reply  Wed Feb 28 19:13:25 2018, gautam, Update, ALS, ADC test for differential receiving in c1lsc c1lsc_ADCtest.png
                                                                   Reply  Fri Mar 2 01:45:06 2018, gautam, Update, ALS, new look ALS electronics IMG_6916.JPG
                                                                      Reply  Mon Mar 5 17:27:34 2018, gautam, Update, ALS, new look ALS electronics - characterization BeatMouthX_20180305_diffOut.pdf
                                                                         Reply  Thu Mar 8 00:40:25 2018, gautam, Update, ALS, new look ALS electronics - characterization BeatMouthX_20180305_diffOut.pdf
                                                                            Reply  Thu Mar 8 19:38:37 2018, gautam, Update, ALS, digital unwhitening of daughter board TFfit.pdf
                                                                               Reply  Thu Mar 8 23:50:27 2018, gautam, Update, ALS, First look at new ALS electronics BeatMouth_OOL.pdf
                                                                                  Reply  Fri Mar 9 01:07:01 2018, gautam, Update, ALS, First look at new ALS electronics ALS_vs_POXnoise.pdf
                                                                                     Reply  Mon Mar 12 22:08:31 2018, gautam, Update, ALS, Noisy POX NoisyPOX_20180312.pdf
                                                                                        Reply  Mon Mar 12 23:57:31 2018, gautam, Update, ALS, Noisy POX NoisyPOXandPOY_20180312.pdfnoisyPOX_Jan2018.pdf
                                                                                           Reply  Mon Mar 19 15:02:29 2018, gautam, Update, ALS, Noisy MC sensing 
                                        Reply  Thu Feb 1 15:31:12 2018, gautam, Update, ALS, ALS signal chain + power budget 
                                        Reply  Wed Feb 7 10:16:26 2018, gautam, Update, ALS, ALS signal chain + power budget 
                      Reply  Thu Jan 25 13:18:41 2018, gautam, Update, ALS, Fiber ALS assay preampProposed.pdf
Message ID: 13574     Entry time: Wed Jan 24 10:45:14 2018     In reply to: 13571
Author: gautam 
Type: Update 
Category: ALS 
Subject: Fiber ALS assay 

I was looking into the physics of polarization maintaining fibers, and then I was trying to remember whether the fibers we use are actually polarization maintaining. Looking up the photos I put in the elog of the fibers when I cleaned them some months ago, at least the short length of fiber attached to the PD doesn't show any stress elements that I did see in the Thorlabs fibers. I'm pretty sure the fiber beam splitters also don't have any stress elements (see Attached photo). So at least ~1m of fiber length before the PD sensing element is probably not PM - just something to keep in mind when thinking about mode overlap and how much beat we actually get.  

 

ELOG V3.1.3-