40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Fri Dec 8 23:31:31 2017, johannes, Frogs, ASS, c1ass slow channel offloading scripts with small
|
Wed Dec 13 09:49:23 2017, johannes, Update, ASS, wiring diagram
|
Thu Dec 14 00:32:56 2017, johannes, Update, ASS, Acromag new crate; c1auxex2 configured as gateway server for acromag 
|
Thu Dec 14 23:27:46 2017, johannes, Update, DAQ, aux chassis design   
|
Tue Jan 9 00:07:03 2018, johannes, Update, DAQ, etmx slow daq chassis
|
Wed Jan 10 22:24:28 2018, johannes, Update, DAQ, etmx slow daq chassis
|
Thu Jan 11 09:57:17 2018, Steve, Update, DAQ, acromag at ETMX
|
Thu Jan 11 20:59:41 2018, gautam, Update, DAQ, etmx slow daq chassis
|
Wed Jan 17 14:32:51 2018, gautam, Update, DAQ, Acromag checks
|
Wed Jan 17 22:44:14 2018, johannes, Update, DAQ, Acromag checks
|
Sun Jan 21 13:11:25 2018, johannes, Update, DAQ, Acromag checks
|
Fri Jan 12 10:02:05 2018, johannes, Update, DAQ, etmx slow daq chassis
|
Fri Jan 12 19:15:34 2018, johannes, Update, DAQ, etmx slow daq chassis
|
Wed Jan 24 18:12:31 2018, johannes, Update, DAQ, ETMX auxiliary DAQ work   
|
Wed Jan 24 19:17:06 2018, johannes, Update, DAQ, c1auxex2 startup behavior
|
Wed Jan 24 23:13:30 2018, johannes, Update, DAQ, c1auxex2 startup behavior
|
Thu Dec 14 19:33:20 2017, gautam, Frogs, ASS, c1ass slow channel offloading scripts with small
|
|
Message ID: 13535
Entry time: Thu Jan 11 20:59:41 2018
In reply to: 13529
Reply to this: 13553
|
Author: |
gautam |
Type: |
Update |
Category: |
DAQ |
Subject: |
etmx slow daq chassis |
|
|
Some suggestions of checks to run, based on the rightmost colum in the wiring diagram here - I guess some of these have been done already, just noting them here so that results can be posted.
- Oplev quadrant slow readouts should match their fast DAQ counterparts.
- Confirm that EX Transmon QPD whitening/gain switching are working as expected, and that quadrant spectra have the correct shape.
- Watchdog tripping under different conditions.
- Coil driver slow readbacks make sense - we should also confirm which of the slow readbacks we are monitoring (there are multiple on the SOS coil driver board) and update the MEDM screen accordingly.
- Confirm that shadow sensor PD whitening is working by looking at spectra.
- Confirm de-whitening switching capability - both to engage and disengage - maybe the procedure here can be repeated.
- Monitor DC alignment of ETMX - we've seen the optic wander around (as judged by the Oplev QPD spot position) while sitting in the control room, would be useful to rule out that this is because of the DC bias voltage stability (it probably isn't).
- Confirm that burt snapshot recording is working as expected - this is not just for c1auxex, but for all channels, since, as Johannes pointed out, the 2018 directory was totally missing and hence no snapshots were being made.
- Confirm that systemd restarts IOC processes when the machine currently called c1auxex2 gets restarted for whatever reason.
|