Entry  Sat Jan 6 05:18:12 2018, Kevin, Update, PonderSqueeze, Displacement requirements for short-term squeezing displacement_noise.pdfnoise_budget.pdf
    Reply  Sat Jan 6 13:47:32 2018, rana, Update, PonderSqueeze, Displacement requirements for short-term squeezing 
       Reply  Sat Jan 6 23:25:18 2018, Kevin, Update, PonderSqueeze, Displacement requirements for short-term squeezing displacement_noise.pdfnoise_budget.pdfangles.pdf
          Reply  Sun Jan 7 03:22:24 2018, Koji, Update, PonderSqueeze, Displacement requirements for short-term squeezing 
             Reply  Sun Jan 7 11:40:58 2018, Kevin, Update, PonderSqueeze, Displacement requirements for short-term squeezing 
                Reply  Sun Jan 7 17:27:13 2018, gautam, Update, PonderSqueeze, Displacement requirements for short-term squeezing 
                   Reply  Sun Jan 7 20:11:54 2018, Koji, Update, PonderSqueeze, Displacement requirements for short-term squeezing 
                      Reply  Thu May 3 00:42:38 2018, Kevin, Update, PonderSqueeze, Coil driver contribution to squeezing noise budget 
Message ID: 13509     Entry time: Sat Jan 6 13:47:32 2018     In reply to: 13508     Reply to this: 13511
Author: rana 
Type: Update 
Category: PonderSqueeze 
Subject: Displacement requirements for short-term squeezing 
  • ought to tune for 210 Hz (in-between powerlines) since 100 Hz is tough to work due to scattering, etc.
  • rename DAC - I think what this curve shows is really the coil driver noise. The DAC noise we can always filter out with the dewhitening board; i.e. once we have 1000x attenuation between the DAC and the coil driver input, DAC noise is not dominant.
ELOG V3.1.3-