40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Wed Nov 29 15:33:16 2017, rana, Update, PSL, PMC locking 
    Reply  Mon Dec 18 20:37:18 2017, gautam, Update, PSL, PMC MEDM cleanup PMC_revamped.png
Message ID: 13457     Entry time: Wed Nov 29 15:33:16 2017     Reply to this: 13488
Author: rana 
Type: Update 
Category: PSL 
Subject: PMC locking 

PMC wasn't locking. Had to power down c1psl. Did burt restore. Still not great.

I think many of the readbacks on the PMC MEDM screen are now bogus and misleading since the PMC RF upgrade that Gautam did awhile ago. We ought to fix the screen and clearly label which readbacks and actuators are no longer valid.

Also, the locking procedure is not so nice. The output V adjust doesn't work anymore with BLANK enabled. Would be good to make an autolocker script if we find a visitor wanting to do something fun.