40m Log |
Not logged in |
 |
|
Mon Oct 9 01:29:26 2017, gautam, Update, LSC, DRMI Nosie Budget v3.0 7x
|
Mon Oct 9 11:55:01 2017, Koji, Update, LSC, DRMI Nosie Budget v3.0
|
Mon Oct 9 22:18:34 2017, gautam, Update, LSC, AS55Q Dark Noise
|
Tue Oct 10 22:04:06 2017, rana, Update, LSC, AS55Q Dark Noise
|
Wed Oct 11 14:42:03 2017, gautam, Update, LSC, AS55Q Dark Noise
|
Wed Oct 11 19:31:32 2017, gautam, Update, LSC, AS55Q Dark Noise
|
Thu Oct 12 01:50:11 2017, gautam, Update, LSC, AS55Q Dark Noise
|
Thu Oct 12 12:17:28 2017, gautam, Update, LSC, AS55Q Dark Noise
|
Fri Oct 13 12:26:12 2017, gautam, Update, LSC, AS55Q Dark Noise
|
Mon Oct 16 16:01:04 2017, gautam, Update, LSC, AS55Q Dark Noise 
|
Tue Oct 17 19:31:53 2017, gautam, Update, LSC, AS55Q Dark Noise 
|
Tue Nov 7 17:45:05 2017, gautam, Update, LSC, DRMI Nosie Budget v3.1   
|
Tue Nov 7 22:56:21 2017, gautam, Update, LSC, DRMI locking recovered
|
Wed Nov 8 00:28:16 2017, gautam, Update, LSC, Laser intensity coupling measurement attempt
|
Wed Nov 8 09:37:45 2017, rana, Update, LSC, DRMI Nosie Budget v3.1
|
Wed Nov 8 09:59:12 2017, gautam, Update, LSC, DRMI Nosie Budget v3.1
|
Wed Nov 15 01:37:07 2017, gautam, Update, LSC, DRMI low freq. nosie improved 
|
Thu Nov 16 00:53:26 2017, gautam, Update, LSC, DRMI noise sub-budgets 
|
|
Message ID: 13414
Entry time: Wed Nov 8 00:28:16 2017
In reply to: 13413
|
Author: |
gautam |
Type: |
Update |
Category: |
LSC |
Subject: |
Laser intensity coupling measurement attempt |
|
|
I tried measuring the coupling of PSL intensity noise by driving some broadband noise bandpassed between 80-300Hz using the spare DAC channel at 1Y3 that I had set up for this purpose a couple of weeks ago (via a battery powered SR560 buffer set to low-noise operation mode because I'm not sure if the DAC output can drive a ~20m long cable). I was monitoring the MC2 TRANS QPD Sum channel spectrum while driving this broadband noise - the "nominal" spectrum isn't very clean, there are a bunch of notches from a 60Hz comb and a forest of peaks over a broad hump from 300Hz-1kHz (see Attachment #1).
I was able to increase the drive to the AOM till the RIN in the band being driven increased by ~10x, and saw no change in the MICH error signal spectrum [see Attachment #1] - during this measurement, the RFPD whitening was turned on for REFL11, REFL55 and AS55, and the ITM coil drivers were de-whitened, so as to get a MICH spectrum that is about as "low-noise" as I've gotten it so far.
I tried increasing the drive further, but at this point, started seeing frequent MC locklosses - I'm not convinced this is entirely correlated to my AOM activities, so I will try some more, but at the very least, this places an upper bound on the coupling from intensity noise to MICH. |
|
|