40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Mon Oct 9 01:29:26 2017, gautam, Update, LSC, DRMI Nosie Budget v3.0 7x
    Reply  Mon Oct 9 11:55:01 2017, Koji, Update, LSC, DRMI Nosie Budget v3.0 
       Reply  Mon Oct 9 22:18:34 2017, gautam, Update, LSC, AS55Q Dark Noise AS55Q_dark.pdf
          Reply  Tue Oct 10 22:04:06 2017, rana, Update, LSC, AS55Q Dark Noise 
          Reply  Wed Oct 11 14:42:03 2017, gautam, Update, LSC, AS55Q Dark Noise AS55Q_darkNoises.pdf
             Reply  Wed Oct 11 19:31:32 2017, gautam, Update, LSC, AS55Q Dark Noise AS55Q_darkNoises.pdf
                Reply  Thu Oct 12 01:50:11 2017, gautam, Update, LSC, AS55Q Dark Noise AS55_dark.png
                   Reply  Thu Oct 12 12:17:28 2017, gautam, Update, LSC, AS55Q Dark Noise D040179_AS55_40m.pdf
                      Reply  Fri Oct 13 12:26:12 2017, gautam, Update, LSC, AS55Q Dark Noise AS55_DemodNoises.pdf
                         Reply  Mon Oct 16 16:01:04 2017, gautam, Update, LSC, AS55Q Dark Noise DemodBoardwOscope.pdfDemodBoardwOscope_ASD.pdf
                            Reply  Tue Oct 17 19:31:53 2017, gautam, Update, LSC, AS55Q Dark Noise D040179_TFs.pdfAS55_DemodNoises.pdf
    Reply  Tue Nov 7 17:45:05 2017, gautam, Update, LSC, DRMI Nosie Budget v3.1 SRCL_MICH_whitenoise_tf.pdfPRCL_MICH_whitenoise_tf.pdfMICH_aux.pdfC1NB_disp_40m_MICH_NB_2017-10-08.pdf
       Reply  Tue Nov 7 22:56:21 2017, gautam, Update, LSC, DRMI locking recovered DRMI_7Nov20178.png
          Reply  Wed Nov 8 00:28:16 2017, gautam, Update, LSC, Laser intensity coupling measurement attempt PSL_RIN.pdf
       Reply  Wed Nov 8 09:37:45 2017, rana, Update, LSC, DRMI Nosie Budget v3.1 
          Reply  Wed Nov 8 09:59:12 2017, gautam, Update, LSC, DRMI Nosie Budget v3.1 
             Reply  Wed Nov 15 01:37:07 2017, gautam, Update, LSC, DRMI low freq. nosie improved C1NB_disp_40m_MICH_NB_2017-11-15.pdfOL_A2L_couplings.pdf
                Reply  Thu Nov 16 00:53:26 2017, gautam, Update, LSC, DRMI noise sub-budgets C1NB_a2l_40m_MICH_NB_2017-11-15.pdfC1NB_aux_40m_MICH_NB_2017-11-15.pdf
Message ID: 13378     Entry time: Thu Oct 12 12:17:28 2017     In reply to: 13376     Reply to this: 13380
Author: gautam 
Type: Update 
Category: LSC 
Subject: AS55Q Dark Noise 

Here is the marked up schematic with the board as it is stuffed. Annoyingly, there is a capacitor (C1) which according to the schematic is supposed to be open, but is stuffed in our board. I can't find any elog about this, and its a pain to measure the value of this capacitance. I will upload all of this + LISO + noise model/measurements to a 40m AS55 daughter board DCC page.

 

Attachment 1: D040179_AS55_40m.pdf  157 kB  | Show | Show all
ELOG V3.1.3-