Wed Oct 4 17:38:25 2017, gautam, Update, LSC, FS725 for Marconi stabilization
|
Thu Oct 5 18:40:27 2017, gautam, Update, LSC, FS725 for Marconi stabilization  
|
Fri Oct 6 00:25:45 2017, rana, Update, LSC, FS725 for Marconi stabilization
|
|
Message ID: 13363
Entry time: Fri Oct 6 00:25:45 2017
In reply to: 13362
|
Author: |
rana |
Type: |
Update |
Category: |
LSC |
Subject: |
FS725 for Marconi stabilization |
|
|
Steve, can you please connect this fan to the rack power and remove this extra power supply?
Quote: |
Re-arranged the DC bench supply on the shelf in the PSL enclosure, whose only purpose seems to be to supply 12V to a fan attached to the rear of the PSL NPRO controller. Seems to be a waste of space! The fan was momentarily disconnected but has since been reconnected and is spinning again.
|
|