40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Mon Aug 14 19:41:46 2017, Jamie, Update, CDS, front-end/DAQ network down for kernel upgrade, and timing errors 
    Reply  Wed Aug 16 17:05:53 2017, Jamie, Update, CDS, front-end/DAQ network down for kernel upgrade, and timing errors 2017-08-16-163725_1366x495_scrot.png
       Reply  Wed Aug 16 17:14:02 2017, Koji, Update, CDS, front-end/DAQ network down for kernel upgrade, and timing errors 
          Reply  Wed Aug 16 18:01:28 2017, Jamie, Update, CDS, front-end/DAQ network down for kernel upgrade, and timing errors 
             Reply  Wed Aug 16 18:06:01 2017, Koji, Update, CDS, front-end/DAQ network down for kernel upgrade, and timing errors 
       Reply  Wed Aug 16 18:50:58 2017, Jamie, Update, CDS, front-end/DAQ network down for kernel upgrade, and timing errors 2017-08-16-184910_1394x488_scrot.png
          Reply  Mon Aug 28 16:20:00 2017, gautam, Update, CDS, 40m files backup situation 
             Reply  Mon Aug 28 17:13:57 2017, ericq, Update, CDS, 40m files backup situation 
             Reply  Fri Sep 15 15:54:28 2017, gautam, Update, CDS, FB wiper script 
                Reply  Mon Sep 18 17:17:49 2017, gautam, Update, CDS, FB wiper script 
                   Reply  Mon Sep 18 17:30:54 2017, Chris, Update, CDS, FB wiper script wiper.pl
                      Reply  Mon Sep 18 17:51:26 2017, gautam, Update, CDS, FB wiper script perlDiff.png
                         Reply  Mon Sep 18 18:40:34 2017, gautam, Update, CDS, FB wiper script 
             Reply  Tue Sep 26 15:55:20 2017, gautam, Update, CDS, 40m files backup situation 
                Reply  Thu Sep 28 10:33:46 2017, gautam, Update, CDS, 40m files backup situation 
                   Reply  Thu Sep 28 11:13:32 2017, jamie, Update, CDS, 40m files backup situation 
                      Reply  Thu Sep 28 23:47:38 2017, gautam, Update, CDS, 40m files backup situation 
                         Reply  Fri Sep 29 11:07:16 2017, gautam, Update, CDS, 40m files backup situation 
                            Reply  Thu Oct 5 13:58:26 2017, gautam, Update, CDS, 40m files backup situation 
                               Reply  Fri Oct 6 12:46:17 2017, gautam, Update, CDS, 40m files backup situation 
                                  Reply  Sat Oct 28 00:36:26 2017, gautam, Update, CDS, 40m files backup situation - ddrescue 415E2F09-3962-432C-B901-DBCB5CE1F6B6.jpegBFF8F8B5-1836-4188-BDF1-DDC0F5B45B41.jpeg
Message ID: 13317     Entry time: Mon Sep 18 17:17:49 2017     In reply to: 13312     Reply to this: 13318
Author: gautam 
Type: Update 
Category: CDS 
Subject: FB wiper script 

After trying to debug this issue using the Perl debugger, I concluded that the problem is in the part of the code that splits the output of the "du" command into directory and disk usage. For whatever, reason, this isn't working. The version of perl running on the new FB1 machine is 5.20.2, whereas I suspect the version running on the old FB machine was 5.14.2 (which is the version on all the Ubuntu 12 workstations and megatron). Unclear whether downgrading the Perl version is the right way to go.

The FB1 disk is now getting close to full, the usage is up to 85% today.

Quote:

Before I go down a Perl rabbit hole, has anyone seen such an error or is aware of some reason why this might not work on the new FB? Am I even using the correct scripts?

 

ELOG V3.1.3-