Entry  Mon Aug 14 19:41:46 2017, Jamie, Update, CDS, front-end/DAQ network down for kernel upgrade, and timing errors 
    Reply  Wed Aug 16 17:05:53 2017, Jamie, Update, CDS, front-end/DAQ network down for kernel upgrade, and timing errors 2017-08-16-163725_1366x495_scrot.png
       Reply  Wed Aug 16 17:14:02 2017, Koji, Update, CDS, front-end/DAQ network down for kernel upgrade, and timing errors 
          Reply  Wed Aug 16 18:01:28 2017, Jamie, Update, CDS, front-end/DAQ network down for kernel upgrade, and timing errors 
             Reply  Wed Aug 16 18:06:01 2017, Koji, Update, CDS, front-end/DAQ network down for kernel upgrade, and timing errors 
       Reply  Wed Aug 16 18:50:58 2017, Jamie, Update, CDS, front-end/DAQ network down for kernel upgrade, and timing errors 2017-08-16-184910_1394x488_scrot.png
          Reply  Mon Aug 28 16:20:00 2017, gautam, Update, CDS, 40m files backup situation 
             Reply  Mon Aug 28 17:13:57 2017, ericq, Update, CDS, 40m files backup situation 
             Reply  Fri Sep 15 15:54:28 2017, gautam, Update, CDS, FB wiper script 
                Reply  Mon Sep 18 17:17:49 2017, gautam, Update, CDS, FB wiper script 
                   Reply  Mon Sep 18 17:30:54 2017, Chris, Update, CDS, FB wiper script wiper.pl
                      Reply  Mon Sep 18 17:51:26 2017, gautam, Update, CDS, FB wiper script perlDiff.png
                         Reply  Mon Sep 18 18:40:34 2017, gautam, Update, CDS, FB wiper script 
             Reply  Tue Sep 26 15:55:20 2017, gautam, Update, CDS, 40m files backup situation 
                Reply  Thu Sep 28 10:33:46 2017, gautam, Update, CDS, 40m files backup situation 
                   Reply  Thu Sep 28 11:13:32 2017, jamie, Update, CDS, 40m files backup situation 
                      Reply  Thu Sep 28 23:47:38 2017, gautam, Update, CDS, 40m files backup situation 
                         Reply  Fri Sep 29 11:07:16 2017, gautam, Update, CDS, 40m files backup situation 
                            Reply  Thu Oct 5 13:58:26 2017, gautam, Update, CDS, 40m files backup situation 
                               Reply  Fri Oct 6 12:46:17 2017, gautam, Update, CDS, 40m files backup situation 
                                  Reply  Sat Oct 28 00:36:26 2017, gautam, Update, CDS, 40m files backup situation - ddrescue 415E2F09-3962-432C-B901-DBCB5CE1F6B6.jpegBFF8F8B5-1836-4188-BDF1-DDC0F5B45B41.jpeg
Message ID: 13312     Entry time: Fri Sep 15 15:54:28 2017     In reply to: 13262     Reply to this: 13317
Author: gautam 
Type: Update 
Category: CDS 
Subject: FB wiper script 

A wiper script is not yet set up for our new Frame-Builder. The disk usage is ~80% now, so I think we should start running a wiper script that manages overall disk usage and deletes old frame files to this end.

From what I could find on the elog, the way this was done was by running a cron job on FB. There is a perl script, /opt/rtcds/caltech/c1/target/fb/wiper.pl, which from what I could understand, runs a bunch of du commands on different directories to determine if there is a need to delete any files.

I copied this script over to /opt/rtcds/caltech/c1/target/daqd/wiper.pl. This is the directory in which all the new FB stuff resides. Conveniently, the script has a "dry-run" option, which I tried running on FB1. However, I get the following error message:

Fri Sep 15 15:44:45 PDT 2017
Dry run, will not remove any files!!!
You need to rerun this with --delete argument to really delete frame files
Directory disk usage:
 /frames/trend/minute_rawk
Combined 0k or 0m or 0Gb
Illegal division by zero at ./wiper.pl line 98.


So it would seem that for some reason, the du commands aren't working. From what I could tell, there aren't any directory paths specific to the old FB machine that need to be changed. I believe the script was working prior to the FB disk crash - unfortunately it doesn't look like this script was under version control but I don't think any changes have been made to this script.

Before I go down a Perl rabbit hole, has anyone seen such an error or is aware of some reason why this might not work on the new FB? Am I even using the correct scripts?

ELOG V3.1.3-