40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Fri Sep 1 15:46:12 2017, Kira, Update, PEM, temp sensor update
|
Tue Sep 5 17:18:17 2017, Kira, Update, PEM, temp sensor update 
|
Tue Sep 5 17:52:06 2017, Kira, Update, PEM, temp sensor update
|
Fri Sep 8 10:22:30 2017, Steve, Update, PEM, temp sensor update
|
Tue Sep 12 11:44:16 2017, Kira, Update, PEM, temp sensor update
|
|
Message ID: 13296
Entry time: Tue Sep 5 17:52:06 2017
In reply to: 13295
Reply to this: 13303
|
Author: |
Kira |
Type: |
Update |
Category: |
PEM |
Subject: |
temp sensor update |
|
|
to get the sensors to read the same values they have to be in direct thermal contact with the metal block - there can't be any adapter board in-between
for the 2nd attempt, I also recommend encasing it in a metal block rather than just one side. You can drill some 7-10 mm diameter holes in an aluminum or copper block. Then put the sensors in there and plug it up with some thermal paste. |