Thu Aug 3 00:59:33 2017, gautam, Update, CDS, NDS2 server restarted, /frames mounted on megatron
|
Thu Aug 3 10:51:32 2017, rana, Update, CDS, NDS2 server restarted, /frames mounted on megatron
|
Thu Aug 3 11:11:29 2017, gautam, Update, CDS, NDS2 server restarted, /frames mounted on nodus
|
Tue Sep 5 14:41:58 2017, gautam, Update, CDS, NDS2 server restarted on megatron
|
Tue Sep 26 13:40:45 2017, gautam, Update, CDS, NDS2 server restarted on megatron
|
|
Message ID: 13293
Entry time: Tue Sep 5 14:41:58 2017
In reply to: 13163
Reply to this: 13331
|
Author: |
gautam |
Type: |
Update |
Category: |
CDS |
Subject: |
NDS2 server restarted on megatron |
|
|
I was unable to download data using nds2. Gabriele had reported similar problems a week ago but I hadn't followed up on this.