40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Mon Mar 6 12:34:30 2017, johannes, Summary, ASS, ASS light injection scenarios 
    Reply  Mon Aug 21 20:11:25 2017, johannes, Summary, General, Loss measurements plan 
       Reply  Mon Aug 21 21:26:41 2017, gautam, Summary, General, Loss measurements plan 
          Reply  Tue Aug 22 16:56:54 2017, johannes, Summary, General, AS laser existing components inventory 
             Reply  Mon Aug 28 23:22:56 2017, johannes, Update, PSL, PSL table auxiliary NPRO aom_switching_zoomin.pngaom_switching_zoomout.pngaom_switching_mini_zoomin.pngaom_switching_mini_zoomout.png
                Reply  Tue Aug 29 20:04:09 2017, rana, Update, PSL, PSL table auxiliary NPRO 
                   Reply  Tue Aug 29 21:36:59 2017, johannes, Update, PSL, PSL table auxiliary NPRO isomet_mini_1st_zoomout.pngisomet_mini_0th_zoomout.png
                      Reply  Tue Sep 5 23:13:44 2017, johannes, Update, PSL, PSL table auxiliary NPRO PSL_IR.pdfpsl_aux_laser.pdf
                         Reply  Thu Sep 7 23:09:00 2017, johannes, Update, PSL, PSL table auxiliary NPRO 3200-1113_200_switching_PD10A_zoomin.png3200-1113_200_switching_PD10A_zoomout.png
                            Reply  Mon Sep 11 12:40:32 2017, johannes, Update, PSL, PSL table auxiliary NPRO psl_aux_laser2.svg.pngPSL_IR2.png
Message ID: 13271     Entry time: Tue Aug 29 21:36:59 2017     In reply to: 13270     Reply to this: 13298
Author: johannes 
Type: Update 
Category: PSL 
Subject: PSL table auxiliary NPRO 
Quote:

 there is a large (~1 cm) aperture Pockels cell that Frank Siefert was using for making pulses to damage photo diodes. There is a DEI Pulser unit near the entrance to the QIL in Bridge which can drive it.

I'll look for it tomorrow, but I haven't given up on the AOMs yet. I swapped in the ISOMET modulator today and saw the same behavior, both in 0th and 1st order. The fall time is pretty much identical. Gautam saw no such thing in the PSL AOM using the same photodetector.

1st order diffracted                                                          0th order

     

In the meantime I prepared the fiber mode-matching but realized in the process that I had mixed up some lenses. As a result the beam did not have a waist at the AOM location and thus didn't have the intended size, although I doubt that this would cause the slower decay. I'll fix it tomorrow, along with setting up the fiber injection, beat note with the PSL, and routing the fiber if possible.