40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Mon Mar 6 12:34:30 2017, johannes, Summary, ASS, ASS light injection scenarios 
    Reply  Mon Aug 21 20:11:25 2017, johannes, Summary, General, Loss measurements plan 
       Reply  Mon Aug 21 21:26:41 2017, gautam, Summary, General, Loss measurements plan 
          Reply  Tue Aug 22 16:56:54 2017, johannes, Summary, General, AS laser existing components inventory 
             Reply  Mon Aug 28 23:22:56 2017, johannes, Update, PSL, PSL table auxiliary NPRO aom_switching_zoomin.pngaom_switching_zoomout.pngaom_switching_mini_zoomin.pngaom_switching_mini_zoomout.png
                Reply  Tue Aug 29 20:04:09 2017, rana, Update, PSL, PSL table auxiliary NPRO 
                   Reply  Tue Aug 29 21:36:59 2017, johannes, Update, PSL, PSL table auxiliary NPRO isomet_mini_1st_zoomout.pngisomet_mini_0th_zoomout.png
                      Reply  Tue Sep 5 23:13:44 2017, johannes, Update, PSL, PSL table auxiliary NPRO PSL_IR.pdfpsl_aux_laser.pdf
                         Reply  Thu Sep 7 23:09:00 2017, johannes, Update, PSL, PSL table auxiliary NPRO 3200-1113_200_switching_PD10A_zoomin.png3200-1113_200_switching_PD10A_zoomout.png
                            Reply  Mon Sep 11 12:40:32 2017, johannes, Update, PSL, PSL table auxiliary NPRO psl_aux_laser2.svg.pngPSL_IR2.png
Message ID: 13236     Entry time: Mon Aug 21 21:26:41 2017     In reply to: 13235     Reply to this: 13241
Author: gautam 
Type: Summary 
Category: General 
Subject: Loss measurements plan 

In case you want to use it, I had profiled the Lightwave NPRO sometime back, and we were even using it as the AUX X laser for a short period of time. 

As for using the AS laser for mode spectroscopy: don't we want to match the beam into the cavity as best as possible, and then use some technique to disturb the input mode (like the dental tooth scraper technique from Chris Mueller's thesis)? 

Johannes and I did an arm scan of the X arm today (arm controlled with ALS, monitoring IR transmission) - only 2 IR FSRs were scanned, but there should be sufficient information in there to extract the modulation depth and mode matching - can we use Kaustubh's/Naomi's code?. The Y arm ALS needs to be touched up so I don't have a Y arm scan yet. Note that to get a good arm scan measurement, the High Gain Thorlabs PD should be used as the transmission PD.

Quote:
 

Week Aug 21 - Aug 27:

  • Update mode-overlap estimates
  • Obtain current DC refl estimates
  • Spatial profile of auxiliary NPRO
  • Fiber setup concept; purchasing
  • CCD software prep work

 