Sat Aug 5 11:04:07 2017, gautam, Update, SUS, MC1 glitches return 
|
Wed Aug 9 15:15:47 2017, gautam, Update, SUS, MC1 glitches return
|
Thu Aug 10 21:01:43 2017, gautam, Update, SUS, MC1 glitches debugging 
|
Fri Aug 11 12:32:46 2017, gautam, Update, SUS, MC1 glitches debugging  
|
Fri Aug 11 17:36:47 2017, gautam, Update, SUS, MC1 <--> MC3
|
Sat Aug 12 14:09:36 2017, gautam, Update, SUS, Glitches stay on MC1  
|
Sat Aug 12 22:35:22 2017, rana, Update, SUS, Glitches stay on MC1
|
Sun Aug 13 01:35:09 2017, Koji, Update, SUS, Glitches stay on MC1
|
Mon Aug 14 20:01:38 2017, gautam, Update, SUS, Glitches stay on MC1
|
Wed Aug 16 19:50:17 2017, gautam, Update, SUS, MC1 <--> MC3 switched back
|
Thu Aug 17 11:17:49 2017, gautam, Update, SUS, MC1 <--> MC3 switched back 
|
Thu Aug 17 17:33:01 2017, gautam, Update, SUS, MC1 <--> MC3 switched back
|
|
Message ID: 13225
Entry time: Thu Aug 17 11:17:49 2017
In reply to: 13220
Reply to this: 13226
|
Author: |
gautam |
Type: |
Update |
Category: |
SUS |
Subject: |
MC1 <--> MC3 switched back |
|
|
Seems like this modification didn't really work. There were several large MC1 glitches, and one of them misaligned MC1 so much that the IMC didn't relock for the last ~6 hours. I re-aligned MC1 manually, and now it is locked fine.
Quote: |
Now that all the CDS overview lights are green, I decided to switch back the coil driver outputs to their original state so that the MC optics could be damped and the IMC relocked. I also restored the static PIT/YAW bias values to their original values.
MC1 has been quiet over the last couple of days, lets see how it behaves in the next few days. In all the glitches I have observed, if the IMC is locked and WFS loops are enabled, the loops are able to correct for the DC misalignment caused by the glitch. But the mcwfs off script is currently set up in such a way that the output history is cleared between IMC locks. I made two copies of the mcwfson/mcwfsoff scripts, called mcwfsunhold/mcwfshold respectively. They live in /opt/rtcds/caltech/c1/scripts/MC/WFS. I've also modified the autolocker script to call these modified scripts, such that when the IMC loses lock, the WFS servo outputs are held, while the input is turned off. The hope is that in this configuration, the autolocker can catch a lock even if there is a glitch on MC1.
I haven't tried locking the arms yet, but I think other IFO work discussed at the meeting (like arm loss estimation / cavity scans etc) can proceed.
|
|
|
|
|