Author: jamie 
Type: Update 
Category: General 
Subject: All FEs down 

I just want to mention that the situation is actually much more dire than we originally thought.  The diskless NFS root filesystem for all the front-ends was on that fb disk.  If we can't recover it we'll have to rebuilt the front end OS as well.

As of right now none of the front ends are accessible, since obviously their root filesystem has disappeared.